VACUUM REGULATING VALVE > INSPECTION |
| 1. INSPECT ELECTRIC VACUUM REGULATING VALVE ASSEMBLY (for EGR) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 11 to 13 Ω |
| 1 - Body ground 2 - Body ground | 20°C (68°F) | 10 MΩ or higher |
![]() |
Check the operation of the electric vacuum regulating valve.
When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.
| *1 | Port E |
| *2 | Port F |
| *3 | Filter |
| *a | Air |
| *b | Vacuum |
![]() |
Apply battery voltage across terminals 1 and 2.
| *1 | Port E |
| *2 | Port F |
| *a | Air |
Check that air flows from port E to port F.
If the result is not as specified, replace the electric EGR control valve assembly.