GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR WITH CLUTCH PULLEY |
![]() |
Hold the center of the generator with clutch pulley, and confirm that the outer ring turns counterclockwise and does not turn clockwise.
![]() | Free |
![]() | Lock |
| 2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the brush length.
| *1 | Length |
| 3. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Inspect that the bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
![]() |
Check the rotor for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Slip ring | 20°C (68°F) | 1.85 to 2.25 Ω |
| *1 | Slip Ring |
![]() |
Check if the rotor is grounded.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Rotor - Slip ring | Always | 10 kΩ or higher |
| *1 | Rotor Core |
| *2 | Slip Ring |
![]() |
Using a vernier caliper, measure each slip ring diameter.