Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1KD-FTV INTAKE

1KD-FTV INTAKE > SERVICE DATA



INTAKE SYSTEM (w/o Glow Plug Controller) 
Turbocharger pressure
Condition
Specified Condition
Engine speed (approximately 4600 rpm)
for Manual Transmission
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)
for Automatic Transmission
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)
Manifold absolute pressure sensor
Condition
Tester Connection
Specified Condition
ECM output voltage
3 VC (+) - 1 E2 (-)
4.75 to 5.25 V
w/ EGR Cooler
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E6-28 (PIM +) - E7-28 (E2 -)
0.0 to 0.3 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.1 to 0.4 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.3 to 0.6 V
w/o EGR Cooler
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E6-28 (PIM +) - E7-28 (E2 -)
0.1 to 0.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.4 to 0.8 V
w/ EGR Cooler
Applied pressure
-
-
19.6 kPa (0.20 mmHg, 2.84 in.Hg)
E6-28 (PIM +) - E7-28 (E2 -)
0.05 to 0.3 V
39.2 kPa (0.40 mmHg, 5.68 in.Hg)
0.25 to 0.55 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
0.45 to 0.75 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
0.65 to 0.95 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
0.9 to 1.2 V
w/o EGR Cooler
Applied pressure
-
-
19.6 kPa (0.20 mmHg, 2.84 in.Hg)
E6-28 (PIM +) - E7-28 (E2 -)
0.1 to 0.4 V
39.2 kPa (0.40 mmHg, 5.68 in.Hg)
0.4 to 0.7 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
0.7 to 1.0 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
1.0 to 1.3 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
1.3 to 1.6 V

INTAKE SYSTEM (w/ Glow Plug Controller) 
Turbocharger pressure
Condition
Specified Condition
Engine speed (approximately 4450 to 4750 rpm)
5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)
Manifold absolute pressure sensor
Condition
Tester Connection
Specified Condition
ECM output voltage
3 VC (+) - 1 E2 (-)
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E30-12 (PIM +) - E30-6 (E2 -)
0.8 to 1.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.5 to 1.0 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.3 to 0.9 V
Applied pressure
-
-
19.6 kPa (0.20 mmHg, 2.84 in.Hg)
E30-12 (PIM +) - E30-6 (E2 -)
1.0 to 1.7 V
39.2 kPa (0.40 mmHg, 5.68 in.Hg)
1.3 to 1.9 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
1.5 to 2.2 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
1.8 to 2.4 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
2.1 to 2.7 V

INTAKE MANIFOLD (w/o Glow Plug Controller) 
Item
Tester Connection
Condition
Specified Condition
Vacuum switching valve (for Swirl Control Valve)
1 - 2
20°C (68°F)
33 to 39 Ω

INTAKE MANIFOLD (w/ Glow Plug Controller) 
Item
Tester Connection
Condition
Specified Condition
No. 1 vacuum switching valve (for Swirl Control Valve)
1 - 2
20°C (68°F)
33 to 39 Ω
No. 2 vacuum switching valve (for Swirl Control Valve)
1 - 2
20°C (68°F)
33 to 39 Ω

TURBOCHARGER 
Turbocharger
Axial play of turbine shaft
Maximum axial play
0.11 mm (0.0043 in.)
Radial play of turbine shaft
Maximum radial play
0.112 mm (0.0044 in.)