DTC 13 Evaporator Temperature Sensor Circuit |
| DTC Code | DTC Detection Condition | Trouble Area |
| 13 | An open or short in evaporator temperature sensor circuit |
|

| 1.INSPECT NO. 1 COOLER THERMISTOR |
![]() |
Remove the No. 1 cooler thermistor (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
| *a | Resistance (kΩ) |
| *b | Temperature |
|
| ||||
| OK | |
| 2.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
![]() |
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A43-1 (TE) - A43-14 (SG-4) |
| 2.0 to 2.4 V |
| 1.4 to 1.8 V |
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
| Result | Proceed to |
| OK (When troubleshooting according to problem symptoms table.) | A |
| OK (When troubleshooting according to DTC.) | B |
| NG | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 1 COOLER THERMISTOR) |
Disconnect the A43 air conditioning amplifier assembly connector.
Disconnect the A19 No. 1 cooler thermistor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A43-1 (TE) - A19-1 | Always | Below 1 Ω |
| A43-14 (SG-4) - A19-2 | ||
| A43-1 (TE) - Body ground | Always | 10 kΩ or higher |
| A43-14 (SG-4) - Body ground |
|
| ||||
| OK | ||
| ||