Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System)

ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System) > INSPECTION

for Preparation Click here



1. INSPECT COOLER THERMISTOR
  1. Remove the cooler thermistor.



    E075750E02
  1. Measure the resistance of the thermistor.

    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    1 - 2
    15°C (59°F)
    2.45 to 2.88 kΩ
    1 - 2
    20°C (68°F)
    1.95 to 2.30 kΩ
    1 - 2
    25°C (77°F)
    1.60 to 1.80 kΩ
    1 - 2
    30°C (86°F)
    1.28 to 1.47 kΩ
    1 - 2
    35°C (95°F)
    1.00 to 1.22 kΩ
    1 - 2
    40°C (104°F)
    0.80 to 1.00 kΩ
    1 - 2
    45°C (113°F)
    0.65 to 0.85 kΩ
    1 - 2
    50°C (122°F)
    0.50 to 0.70 kΩ
    1 - 2
    55°C (131°F)
    0.44 to 0.60 kΩ
    1 - 2
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring the resistance, the thermistor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see graph).