Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › SOLAR SENSOR (for Automatic Air Conditioning System)

SOLAR SENSOR (for Automatic Air Conditioning System) > INSPECTION

for Preparation Click here



1. INSPECT SOLAR SENSOR
  1. Remove the solar sensor.



  1. Measure the resistance of the sensor.



      E072857E01
    1. Connect the ohmmeter's negative (-) lead to terminal 1 and positive (+) lead to terminal 2.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      Sensor is subjected to electric light
      Below 1 MΩ
      1 - 2
      Sensor is covered with a cloth
      1 MΩ or higher

      NOTICE:
      The connection procedure for a digital tester, such as a TOYOTA electrical tester, is shown above. When using an analog tester, connect the negative (-) lead to terminal 2 and positive (+) lead to terminal 1.

      HINT:
      1. As the inspection light is moved away from the sensor, the resistance increases.
      2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the A/C solar sensor.