1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY


  1. Measure the resistance of the power switch.


    B112777E01


    Standard resistance:
    Driver switch:

    Window Lock Switch Condition
    Power Switch Condition
    Tester Connection
    Specified Condition
    Always
    (ON / OFF)
    UP
    3 (E) - 9 (DD)
    4 (DU) - 6 (B)
    Below 1 Ω
    Always
    (ON / OFF)
    OFF
    3 (E) - 4 (DU)
    3 (E) - 9 (DD)
    Below 1 Ω
    Always
    (ON / OFF)
    DOWN
    3 (E) - 4 (DU)
    6 (B) - 9 (DD)
    Below 1 Ω
    Always
    (ON / OFF)
    AUTO DOWN
    3 (E) - 4 (DU)
    6 (B) - 9 (DD)
    Below 1 Ω
    Front passenger switch:

    Window Lock Switch Condition
    Power Switch Condition
    Tester Connection
    Specified Condition
    OFF
    UP
    3 (E) - 15 (PD)
    6 (B) - 18 (PU)
    Below 1 Ω
    OFF
    OFF
    3 (E) - 18 (PU)
    3 (E) - 15 (PD)
    Below 1 Ω
    OFF
    DOWN
    3 (E) - 18 (PU)
    6 (B) - 15 (PD)
    Below 1 Ω
    ON
    UP
    3 (E) - 15 (PD)
    10 kΩor higher
    6 (B) - 18 (PU)
    Below 1 Ω
    ON
    OFF
    18 (PU) - 15 (PD)
    Below 1 Ω
    ON
    DOWN
    3 (E) - 18 (PU)
    10 kΩor higher
    6 (B) - 15 (PD)
    Below 1 Ω
    Rear LH switch:

    Window Lock Switch Condition
    Power Switch Condition
    Tester Connection
    Specified Condition
    OFF
    UP
    3 (E) - 13 (RLD)
    6 (B) - 12 (RLU)
    Below 1 Ω
    OFF
    OFF
    3 (E) - 12 (RLU)
    3 (E) - 13 (RLD)
    Below 1 Ω
    OFF
    DOWN
    3 (E) - 12 (RLU)
    6 (B) - 13 (RRD)
    Below 1 Ω
    ON
    UP
    3 (E) - 13 (RLD)
    10 kΩor higher
    6 (B) - 12 (RLU)
    Below 1 Ω
    ON
    OFF
    12 (RLU) - 13 (RLD)
    Below 1 Ω
    ON
    DOWN
    3 (E) - 12 (RLU)
    10 kΩor higher
    6 (B) - 13 (RLD)
    Below 1 Ω
    Rear RH switch:

    Window Lock Switch Condition
    Power Switch Condition
    Tester Connection
    Specified Condition
    OFF
    UP
    3 (E) - 16 (RRD)
    6 (B) - 10 (RRU)
    Below 1 Ω
    OFF
    OFF
    3 (E) - 10 (RRU)
    3 (E) - 16 (RRD)
    Below 1 Ω
    OFF
    DOWN
    3 (E) - 10 (RRU)
    6 (B) - 16 (RRD)
    Below 1 Ω
    ON
    UP
    3 (E) - 16 (RRD)
    10 kΩor higher
    6 (B) - 10 (RRU)
    Below 1 Ω
    ON
    OFF
    10 (RRU) - 16 (RRD)
    Below 1 Ω
    ON
    DOWN
    3 (E) - 10 (RRU)
    10 kΩor higher
    6 (B) - 16 (RRD)
    Below 1 Ω

    1. If the result is not as specified, replace the switch assembly.



    B079808E01
  1. Apply battery voltage to the master switch and check that the AUTO light illuminates.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 6 (B)
    Battery negative (-) → Terminal 3 (E)
    AUTO light illuminates

    1. If the result is not as specified, replace the switch assembly.