POWER WINDOW MASTER SWITCH (w/o Jam Protection Function) > INSPECTION |
| 1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
Measure the resistance of the power switch.

| Window Lock Switch Condition | Power Switch Condition | Tester Connection | Specified Condition |
| Always (ON / OFF) | UP | 3 (E) - 9 (DD) 4 (DU) - 6 (B) | Below 1 Ω |
| Always (ON / OFF) | OFF | 3 (E) - 4 (DU) 3 (E) - 9 (DD) | Below 1 Ω |
| Always (ON / OFF) | DOWN | 3 (E) - 4 (DU) 6 (B) - 9 (DD) | Below 1 Ω |
| Always (ON / OFF) | AUTO DOWN | 3 (E) - 4 (DU) 6 (B) - 9 (DD) | Below 1 Ω |
| Window Lock Switch Condition | Power Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 3 (E) - 15 (PD) 6 (B) - 18 (PU) | Below 1 Ω |
| OFF | OFF | 3 (E) - 18 (PU) 3 (E) - 15 (PD) | Below 1 Ω |
| OFF | DOWN | 3 (E) - 18 (PU) 6 (B) - 15 (PD) | Below 1 Ω |
| ON | UP | 3 (E) - 15 (PD) | 10 kΩor higher |
| 6 (B) - 18 (PU) | Below 1 Ω | ||
| ON | OFF | 18 (PU) - 15 (PD) | Below 1 Ω |
| ON | DOWN | 3 (E) - 18 (PU) | 10 kΩor higher |
| 6 (B) - 15 (PD) | Below 1 Ω |
| Window Lock Switch Condition | Power Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 3 (E) - 13 (RLD) 6 (B) - 12 (RLU) | Below 1 Ω |
| OFF | OFF | 3 (E) - 12 (RLU) 3 (E) - 13 (RLD) | Below 1 Ω |
| OFF | DOWN | 3 (E) - 12 (RLU) 6 (B) - 13 (RRD) | Below 1 Ω |
| ON | UP | 3 (E) - 13 (RLD) | 10 kΩor higher |
| 6 (B) - 12 (RLU) | Below 1 Ω | ||
| ON | OFF | 12 (RLU) - 13 (RLD) | Below 1 Ω |
| ON | DOWN | 3 (E) - 12 (RLU) | 10 kΩor higher |
| 6 (B) - 13 (RLD) | Below 1 Ω |
| Window Lock Switch Condition | Power Switch Condition | Tester Connection | Specified Condition |
| OFF | UP | 3 (E) - 16 (RRD) 6 (B) - 10 (RRU) | Below 1 Ω |
| OFF | OFF | 3 (E) - 10 (RRU) 3 (E) - 16 (RRD) | Below 1 Ω |
| OFF | DOWN | 3 (E) - 10 (RRU) 6 (B) - 16 (RRD) | Below 1 Ω |
| ON | UP | 3 (E) - 16 (RRD) | 10 kΩor higher |
| 6 (B) - 10 (RRU) | Below 1 Ω | ||
| ON | OFF | 10 (RRU) - 16 (RRD) | Below 1 Ω |
| ON | DOWN | 3 (E) - 10 (RRU) | 10 kΩor higher |
| 6 (B) - 16 (RRD) | Below 1 Ω |
![]() |
Apply battery voltage to the master switch and check that the AUTO light illuminates.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 6 (B) Battery negative (-) → Terminal 3 (E) | AUTO light illuminates |