Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2KD-FTV INTAKE

2KD-FTV INTAKE > SERVICE DATA



TURBOCHARGER PRESSURE 
Condition
Specified Condition
Engine speed (approximately 4600 rpm)
10 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)

MANIFOLD ABSOLUTE PRESSURE SENSOR 
Condition
Tester connection
Specified Condition
ECM output voltage
T9-3 (VC (+)) - T9-1 (E2 (-))
4.75 to 5.25 V
Applied vacuum
-
-
13.3 kPa (100 mmHg, 3.94 in.Hg)
E6-28 (PIM) - E7-28 (E2)
0.1 to 0.4 V
26.6 kPa (199 mmHg, 7.85 in.Hg)
0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg)
0.4 to 0.8 V
Applied pressure
-
-
19.6 kPa (0.20 mmHg, 2.84 in.Hg)
E6-28 (PIM) - E7-28 (E2)
0.1 to 0.4 V
39.2 kPa (0.40 mmHg, 5.69 in.Hg)
0.4 to 0.7 V
58.8 kPa (0.60 mmHg, 8.53 in.Hg)
0.7 to 1.0 V
78.5 kPa (0.80 mmHg, 11.4 in.Hg)
1.0 to 1.3 V
98.0 kPa (1.00 mmHg, 14.2 in.Hg)
1.3 to 1.6 V

TURBOCHARGER 
Condition
Specified Condition
Maximum axial play of turbine shaft
0.08 mm (0.0031 in.)
Maximum radial play of turbine shaft
0.110 mm (0.0043 in.)
Actuator and waste gate valve operation
108 kPa (1.1 kgf*cm2, 16 psi)