Home › ENGINE · 2TR-FBE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > ECM Power Source Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch is turned to ON, battery voltage is applied to terminal IGSW of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (MAIN relay) and supplying power to terminal +B of the ECM.

WIRING DIAGRAM


A242465E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E23-5 (E1) - Body ground
    Always
    Below 1 Ω

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - BODY GROUND)
OK


2.INSPECT ECM (IGSW VOLTAGE)


    A177861E66
  1. Disconnect the ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    E25-22 (IGSW) - Body ground
    Ignition switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)

  1. Reconnect the ECM connector.



NG
Go to step 8
OK


3.INSPECT INTEGRATION RELAY (MAIN)
  1. Inspect the integration relay (MAIN relay) (Click here).



NG
REPLACE INTEGRATION RELAY (MAIN)
OK


4.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY [MAIN] - ECM)
  1. Remove the integration relay (MAIN relay) from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1J-4 - E24-23 (+B)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    1J-4 or E24-23 (+B) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the integration relay connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION RELAY [MAIN] - ECM)
OK


5.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY [MAIN] - BATTERY)
  1. Remove the integration relay (MAIN relay) from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect the cable from the positive (+) battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1H-1 - Positive battery terminal
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    1H-1 or Positive battery terminal - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the integration relay connector.

  1. Reinstall the integration relay.

  1. Reconnect the cable to the positive (+) battery terminal.

  1. Reconnect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION RELAY [MAIN] - BATTERY)
OK


6.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY [MAIN] - BODY GROUND)
  1. Remove the integration relay (MAIN relay) from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1J-3 - Body ground
    Always
    Below 1 Ω

  1. Reconnect the integration relay connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION RELAY [MAIN] - BODY GROUND)
OK


7.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY [MAIN] - ECM)
  1. Disconnect the ECM connector.

  1. Remove the integration relay (MAIN relay) from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1J-2 - E25-12 (MREL)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    1J-2 or E25-12 (MREL) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the integration relay connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (INTEGRATION RELAY [MAIN] - ECM)
OK

REPLACE ECM (Click here)  

8.INSPECT IGNITION SWITCH ASSEMBLY


    B119736E21
  1. Disconnect the ignition switch assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 (AM2) - 6 (IG2)
    LOCK
    10 kΩ or higher
    5 (AM2) - 6 (IG2)
    ON
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Ignition Switch Assembly)

  1. Reconnect the ignition switch assembly connector.



NG
REPLACE IGNITION SWITCH ASSEMBLY
OK


9.CHECK HARNESS AND CONNECTOR (IGNITION SWITCH ASSEMBLY - ECM)
  1. Disconnect the ECM connector.

  1. Disconnect the ignition switch assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    E25-22 (IGSW) - I8-6 (IG2)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    E25-22 (IGSW) or I8-6 (IG2) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the ignition switch assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH ASSEMBLY - ECM)
OK


10.CHECK HARNESS AND CONNECTOR (IGNITION SWITCH ASSEMBLY - BATTERY)
  1. Disconnect the ignition switch assembly connector.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect the cable from the positive (+) battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    I8-5 (AM2) - Positive battery terminal
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    I8-5 (AM2) or Positive battery terminal - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ignition switch assembly connector.

  1. Reconnect the cable to the positive (+) battery terminal.

  1. Reconnect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH ASSEMBLY - BATTERY)
OK

REPLACE ECM (Click here)