Home › ENGINE ยท 1KD-FTV › EMISSION CONTROL › VACUUM SWITCHING VALVE (w/ Glow Plug Controller)

VACUUM SWITCHING VALVE (w/ Glow Plug Controller) > REMOVAL

for Preparation Click here



1. REMOVE MANIFOLD STAY WITH VACUUM SWITCHING VALVE


    A271765
  1. Disconnect the connector and 2 No. 2 vacuum transmitting hoses and detach the 2 clamps.



    A271766
  1. Remove the 2 bolts and manifold stay with vacuum switching valve.



2. REMOVE VACUUM SWITCHING VALVE (for EGR Bypass Valve)


    A253534
  1. Remove the screw and vacuum switching valve.