COMMON RAIL (w/o Glow Plug Controller) > INSPECTION |
| 1. INSPECT COMMON RAIL ASSEMBLY |
![]() |
Inspect the fuel pressure sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 - 3 | 25°C (77°F) | 16.4 kΩ or less |
| 5 - 4 | 25°C (77°F) | 16.4 kΩ or less |
| 1 - 2 | 25°C (77°F) | 3 kΩ or less |
| 6 - 5 | 25°C (77°F) | 3 kΩ or less |
Inspect the pressure discharge valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 0.85 to 1.05 Ω |