COOLANT > REPLACEMENT |
| 1. REMOVE NO. 1 ENGINE UNDER COVER |
| 2. DRAIN ENGINE COOLANT |
Remove the radiator cap.
Loosen the cylinder block drain cock plug and radiator drain cock plug to drain the coolant.

| 3. ADD ENGINE COOLANT |
Tighten all the plugs and fill the radiator with TOYOTA Super Long Life Coolant (SLLC).
| Item | Specified Condition |
| A/T | 8.1 liters (8.6 US qts, 7.1 Imp. qts) |
| M/T | 7.8 liters (8.2 US qts, 6.9 Imp. qts) |
Fill the radiator reservoir with TOYOTA SLLC to the F line.
Press the inlet and outlet radiator hoses several times by hand, and then check the level of the coolant.
If the coolant level drops below the F line, add TOYOTA SLLC to the F line.
Install the radiator cap.
Bleed air from the cooling system.
Warm up the engine until the thermostat opens.
While the thermostat is open, circulate the coolant for several minutes.
Maintain the engine speed at 2500 to 3000 rpm.
Press the inlet and outlet radiator hoses several times by hand to bleed air.
Stop the engine and wait until the coolant cools down to ambient temperature.
Check the coolant level in the radiator reservoir.
If the coolant level is below the L line, add SLLC up to the reservoir F line.
| 4. INSPECT FOR COOLANT LEAK |
Fill the radiator with coolant and attach a radiator cap tester.
Warm up the engine.
Using a radiator cap tester, increase the pressure inside the radiator to 118 kPa (1.2 kgf/cm2, 17 psi), and check that the pressure does not drop.
If the pressure drops, check the hoses, radiator and water pump for leaks. If no external leaks are found, check the cylinder block and cylinder head.
| 5. INSTALL NO. 1 ENGINE UNDER COVER |