Home › ENGINE · 1KD-FTV › ENGINE CONTROL SYSTEM › ECD SYSTEM (w/ EGR Cooler)

DTC    P245C    EGR Cooler Bypass Control Circuit Low

DTC    P245D    EGR Cooler Bypass Control Circuit High

for Preparation Click here


DESCRIPTION

The vacuum switching valve (for EGR bypass valve) is controlled by the ECM, and the opening and closing of the EGR cooler bypass valve is performed according to the vacuum applied by the vacuum pump.

P245C 
DTC Detection Drive Pattern
DTC Detection Condition
Trouble Area
Ignition switch to ON for 3 seconds
Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic).
  1. Open or short in vacuum switching valve (for EGR bypass valve) circuit
  2. Vacuum switching valve (for EGR bypass valve)
  3. ECM

P245D 
DTC Detection Drive Pattern
DTC Detection Condition
Trouble Area
Ignition switch to ON for 3 seconds
Open or short in the vacuum switching valve (for EGR bypass valve) for 3 seconds (1 trip detection logic).
  1. Open or short in vacuum switching valve (for EGR bypass valve) circuit
  2. Vacuum switching valve (for EGR bypass valve)
  3. ECM

WIRING DIAGRAM


A155670E08


INSPECTION PROCEDURE

NOTICE:
  1. After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
  2. Inspect the fuses of circuits related to this system before performing the following inspection procedure.

1.INSPECT VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE)
  1. Inspect the vacuum switching valve (for EGR bypass valve) .



NG
Go to step 5
OK


2.CHECK VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) (POWER SOURCE CIRCUIT)


    A154589E40
  1. Disconnect the vacuum switching valve (for EGR bypass valve) connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    V7-1 - Body ground
    Ignition switch to ON
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Vacuum Switching Valve (for EGR Bypass Valve))

  1. Reconnect the vacuum switching valve (for EGR bypass valve) connector.



NG
Go to step 6
OK


3.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE) - ECM)
  1. Disconnect the vacuum switching valve (for EGR bypass valve) connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    V7-2 - E6-19 (ECBV)
    Always
    Below 1 Ω
    V7-2 or E6-19 (ECBV) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the vacuum switching valve (for EGR bypass valve) connector.

  1. Reconnect the ECM connector.



NG
Go to step 6
OK


4.REPLACE ECM
  1. Replace the ECM (Click here).



NEXT
Go to step 7

5.REPLACE VACUUM SWITCHING VALVE (FOR EGR BYPASS VALVE)
  1. Replace the vacuum switching valve (for EGR bypass valve).



NEXT
Go to step 7

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
  1. Repair or replace the harness or connector.

    HINT:
    If the voltage at the vacuum switching valve (for EGR bypass valve) connector is not 11 to 14 V, repair or replace the harness and connector between the vacuum switching valve (for EGR bypass valve) and MAIN relay.


NEXT


7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
  1. Connect the intelligent tester to the DLC3.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch to ON for 3 seconds.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Confirm that the DTC is not output again.


NEXT

END