INTAKE MANIFOLD (w/ Glow Plug Controller) > INSPECTION |
| 1. INSPECT INTAKE MANIFOLD |
![]() |
Check the operation of the swirl control valve.
Check that the valve is fully opened under normal conditions.
Connect the vacuum pumps as shown in the illustration. First apply negative pressure to the diaphragm closer to the intake manifold. This will cause the actuator rod to move, which causes the swirl control valve to move. Then, apply negative pressure to the diaphragm on the outer side. This will cause the actuator rod to move further, which also causes the swirl control valve to move further. Check that the valve is fully closed when a negative pressure of 35 kPa (270 mmHg, 10 in.Hg) is applied.

Leave it for 1 minute and check that the vacuum pump needle does not move. If the result is not as specified, replace the intake manifold.
| 2. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground 2 - Body ground | 20°C (68°F) | 10 kΩ or higher |
![]() |
Check the operation according to the value(s) in the table below.
| *1 | Port E |
| *2 | Filter |
![]() | Airflow |
Check that air flows from port E to the filter.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
![]() |
Apply battery voltage across the terminals.
| *1 | Port E |
| *2 | Port F |
![]() | Airflow |
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
| 3. INSPECT NO. 2 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground 2 - Body ground | 20°C (68°F) | 10 kΩ or higher |
![]() |
Check the operation according to the value(s) in the table below.
| *1 | Port E |
| *2 | Filter |
![]() | Airflow |
Check that air flows from port E to the filter.
If the result is not as specified, replace the No. 2 vacuum switching valve assembly.
![]() |
Apply battery voltage across the terminals.
| *1 | Port E |
| *2 | Port F |
![]() | Airflow |
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 2 vacuum switching valve assembly.