Home › ENGINE · 1KD-FTV › INTAKE › INTAKE MANIFOLD (w/ Glow Plug Controller)

INTAKE MANIFOLD (w/ Glow Plug Controller) > INSPECTION

for Preparation Click here



1. INSPECT INTAKE MANIFOLD

NOTICE:
A271911
Do not adjust the adjusting screw or 2 swirl control valve actuator installation bolts.



  1. Check the operation of the swirl control valve.

    1. Check that the valve is fully opened under normal conditions.



    2. Connect the vacuum pumps as shown in the illustration. First apply negative pressure to the diaphragm closer to the intake manifold. This will cause the actuator rod to move, which causes the swirl control valve to move. Then, apply negative pressure to the diaphragm on the outer side. This will cause the actuator rod to move further, which also causes the swirl control valve to move further. Check that the valve is fully closed when a negative pressure of 35 kPa (270 mmHg, 10 in.Hg) is applied.


      A149795

      HINT:
      When applying negative pressure to the diaphragm on the outer side, the diaphragm closer to the intake manifold must be in a vacuum state.

    3. Leave it for 1 minute and check that the vacuum pump needle does not move. If the result is not as specified, replace the intake manifold.



2. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    33 to 39 Ω
    1 - Body ground
    2 - Body ground
    20°C (68°F)
    10 kΩ or higher

    If the result is not as specified, replace the No. 1 vacuum switching valve assembly.



    G037162E03
  1. Check the operation according to the value(s) in the table below.
    Text in Illustration 
    *1
    Port E
    *2
    Filter
    V100135
    Airflow

    1. Check that air flows from port E to the filter.
      If the result is not as specified, replace the No. 1 vacuum switching valve assembly.



    2. A110309E04
    3. Apply battery voltage across the terminals.
      Text in Illustration 
      *1
      Port E
      *2
      Port F
      V100135
      Airflow

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the No. 1 vacuum switching valve assembly.



3. INSPECT NO. 2 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    33 to 39 Ω
    1 - Body ground
    2 - Body ground
    20°C (68°F)
    10 kΩ or higher

    If the result is not as specified, replace the No. 2 vacuum switching valve assembly.



    G037162E03
  1. Check the operation according to the value(s) in the table below.
    Text in Illustration 
    *1
    Port E
    *2
    Filter
    V100135
    Airflow

    1. Check that air flows from port E to the filter.
      If the result is not as specified, replace the No. 2 vacuum switching valve assembly.



    2. A110309E04
    3. Apply battery voltage across the terminals.
      Text in Illustration 
      *1
      Port E
      *2
      Port F
      V100135
      Airflow

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the No. 2 vacuum switching valve assembly.