Home › BODY ELECTRICAL › METER › ACCESSORY METER

ACCESSORY METER > REMOVAL

for Preparation Click here



1. REMOVE UPPER INSTRUMENT PANEL SUB-ASSEMBLY
(Click here)


2. REMOVE AUTO CLOCK HOLE BEZEL


B277294
  1. Remove the 2 screws.

  1. Disconnect the connector and remove the auto clock hole bezel.



3. REMOVE ACCESSORY METER ASSEMBLY


B277295
  1. Remove the 2 screws.



    B277296E01
  1. Using a screwdriver, detach the 3 claws and remove the accessory meter.

    HINT:
    Tape the screwdriver tip before use.

    Text in Illustration 
    *1
    Protective Tape