Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2KD-FTV COOLING

2KD-FTV COOLING > SERVICE DATA



THERMOSTAT 
Condition
Specified Condition
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 mm (0.394 in.) or more at 95°C (203°F)

RADIATOR RESERVOIR CAP 
Item
Specified Condition
Standard value
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value
(after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)