BLOWER UNIT > DISASSEMBLY |
| 1. REMOVE AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System) |
![]() |
Detach the 3 claws and remove the air inlet damper control cable sub-assembly.
| 2. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System) |
![]() |
Detach the claw and remove the lever.
| *1 | Lever |
![]() |
Remove the 3 screws and recirculation damper servo sub-assembly.
| 3. REMOVE CLEAN AIR FILTER |
![]() |
Detach the claw and remove the air filter case.
Remove the clean air filter.
| 4. REMOVE BLOWER RESISTOR (for Manual Air Conditioning System) |
![]() |
Remove the 2 screws and blower resistor.
| 5. REMOVE BLOWER MOTOR CONTROL (for Automatic Air Conditioning System) |
![]() |
Remove the 2 screws and blower motor control.
| 6. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY |
![]() |
Remove the 3 screws and blower motor with fan sub-assembly.