Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › BLOWER UNIT

BLOWER UNIT > DISASSEMBLY

for Preparation Click here



1. REMOVE AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)


E227247
  1. Detach the 3 claws and remove the air inlet damper control cable sub-assembly.



2. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)


    E229501E01
  1. Detach the claw and remove the lever.
    Text in Illustration 
    *1
    Lever



    E229502
  1. Remove the 3 screws and recirculation damper servo sub-assembly.



3. REMOVE CLEAN AIR FILTER


E225195
  1. Detach the claw and remove the air filter case.

  1. Remove the clean air filter.



4. REMOVE BLOWER RESISTOR (for Manual Air Conditioning System)


    E233809
  1. Remove the 2 screws and blower resistor.



5. REMOVE BLOWER MOTOR CONTROL (for Automatic Air Conditioning System)


    E233808
  1. Remove the 2 screws and blower motor control.



6. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    E233172
  1. Remove the 3 screws and blower motor with fan sub-assembly.