Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › BLOWER UNIT

BLOWER UNIT > REASSEMBLY

for Preparation Click here



1. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY
  1. Install the blower motor with fan sub-assembly with 3 screws.



2. INSTALL BLOWER RESISTOR (for Manual Air Conditioning System)
  1. Install the blower resistor with 2 screws.



3. INSTALL BLOWER MOTOR CONTROL (for Automatic Air Conditioning System)
  1. Install the blower motor control with 2 screws.



4. INSTALL CLEAN AIR FILTER
  1. Install the clean air filter.

  1. Attach the claw to install the air filter case.



5. INSTALL AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)
  1. Attach the 3 claws to install the air inlet damper control cable sub-assembly.



6. INSTALL RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)
  1. Install the recirculation damper servo sub-assembly with 3 screws.

  1. Attach the claw to install the recirculation damper servo sub-assembly.