Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2KD-FTV FUEL

2KD-FTV FUEL > SERVICE DATA



FUEL INJECTOR 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
0.42 to 0.52 Ω

FUEL SUPPLY PUMP 
Item
Tester Connection
Condition
Specified Condition
Suction control valve
1 - 2
20°C (68°F)
1.9 to 2.3 Ω
Fuel temperature sensor
1 - 2
20°C (68°F)
2.32 to 2.59 kΩ

COMMON RAIL 
Item
Tester Connection
Condition
Specified Condition
Fuel pressure sensor
2 - 3
25°C (77°F)
16.4 kΩ or less
5 - 4
25°C (77°F)
16.4 kΩ or less
1 - 2
25°C (77°F)
3 kΩ or less
6 - 5
25°C (77°F)
3 kΩ or less
Pressure discharge valve
1 - 2
20°C (68°F)
0.85 to 1.05 Ω

FUEL FILTER 
Item
Tester Connection
Condition
Specified Condition
Level warning switch
1 - 2
Float at upper end position
Below 1 Ω
Float at lower end position
10 kΩ or higher
Clogging switch
1 - 2
20°C (68°F)
Below 1 Ω