HEATING / AIR CONDITIONING  AIR CONDITIONING PANEL(for Manual Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 55900 1.INSPECT AIR CONDITIONING CONTROL ASSEMBLY

a.
E319586C01
1.083,0.927 1.24,0.219 1.24,0.219 1.51,0.219 true 2.469,1.49 2.594,1.917 2.594,1.917 2.865,1.917 true 1.656,1.521 1.792,1.896 1.792,1.896 2.042,1.896 true 1.427,1.521 1.583,2.031 1.583,2.031 1.833,2.031 true 1.115,1.531 1.24,1.958 1.24,1.958 1.031,1.958 true 0.104,0.083 0.417,0.281 0.313,0.198 10 false *a 1.563,0.146 1.719,0.344 0.156,0.198 10 false E 0.802,1.875 1.031,2.063 0.229,0.188 10 false M2 1.875,1.958 2.125,2.146 0.25,0.188 10 false LO 2.094,1.802 2.323,1.99 0.229,0.188 10 false M1 2.896,1.844 3.125,2.031 0.229,0.188 10 false HI
*a Component without harness connected
(Air Conditioning Control Assembly)


Check the blower switch resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 (LO), 6 (HI), 8 (M1) or 10 (M2) - 5 (E) OFF 10 kΩ or higher
9 (LO) - 5 (E) Blower Switch 1 Below 1 Ω
9 (LO) or 8 (M1) - 5 (E) Blower Switch 1 - 2 Below 1 Ω
9 (LO) or 8 (M1) - 5 (E) Blower Switch 2 Below 1 Ω
9 (LO), 8 (M1) or 10 (M2) - 5 (E) Blower Switch 2 - 3 Below 1 Ω
9 (LO) or 10 (M2) - 5 (E) Blower Switch 3 Below 1 Ω
9 (LO), 6 (HI) or 10 (M2) - 5 (E) Blower Switch 3 - 4 Below 1 Ω
9 (LO) or 6 (HI) - 5 (E) Blower Switch 4 Below 1 Ω


If the result is not as specified, replace the air conditioning control assembly.



b.
E319585C12
1.229,0.375 1.417,0.375 1.417,0.375 1.521,1.021 true 1.99,1.792 1.781,1.792 1.781,1.792 1.594,1.344 true 0.042,0.031 0.354,0.188 0.313,0.156 10 false *a 0.896,0.313 1.354,0.51 0.458,0.198 10 false ACE 2.031,1.708 2.49,1.906 0.458,0.198 10 false A/C
*a Component without harness connected
(Air Conditioning Control Assembly)


Check the A/C switch resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (ACE) - 9(A/C) OFF 10 kΩ or higher
4 (ACE) - 9 (A/C) ON Below 1 Ω


If the result is not as specified, replace the air conditioning control assembly.



c.
E322298C04
0.792,0.927 0.823,0.375 0.823,0.375 1.031,0.375 false 2.063,0.292 2.302,0.292 2.302,0.292 2.458,1.031 true 3.094,1.813 2.885,1.813 2.885,1.813 2.792,1.375 true 0.063,0.073 0.375,0.229 0.313,0.156 10 false *a 1.083,0.292 1.396,0.448 0.313,0.156 10 false *b 3.125,1.74 3.281,1.938 0.156,0.198 10 false B 1.75,0.229 2.094,0.438 0.344,0.208 10 false ACE
*a Component without harness connected
(Air Conditioning Control Assembly (A/C Switch))
*b Indicator


Check that the A/C switch LED illuminates.

i.

Apply battery voltage to the air conditioning control assembly (A/C switch) and check that the LED illuminates.

OK:
Measurement Condition Condition Specified Condition
Battery positive (+) → 7 (B)
Battery negative (-) → 4 (ACE)
A/C Switch ON Indicator illuminates


If the result is not as specified, replace the air conditioning control assembly.



d.
E319585C08
1.083,0.385 1.271,0.385 1.271,0.385 1.375,1.031 true 2.135,0.385 1.979,0.385 1.979,0.385 1.896,1.021 true 2.135,1.083 2.604,1.083 true 0.042,0.031 0.354,0.188 0.313,0.156 10 false *a 2.177,0.313 2.635,0.51 0.458,0.198 10 false LED+ 0.708,0.313 1.167,0.51 0.458,0.198 10 false ERDF 2.646,1.021 3.104,1.219 0.458,0.198 10 false FRS
*a Component without harness connected
(Air Conditioning Control Assembly)


Check the recirculation/fresh switch resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (FRS) - 5 (ERDF) OFF Below 1 Ω
2 (LED+) - 5 (ERDF) OFF 10 kΩ or higher
2 (LED+) - 5 (ERDF) ON Below 1 Ω
1 (FRS) - 5 (ERDF) ON 10 kΩ or higher


If the result is not as specified, replace the air conditioning control assembly.



e.
E325135C01
0.833,0.917 0.865,0.396 0.865,0.396 1.052,0.396 true 2.563,1.01 2.688,0.354 2.688,0.354 2.885,0.354 true 2.24,1.021 2.396,0.146 2.396,0.146 2.594,0.146 true 0.052,0.042 0.365,0.198 0.313,0.156 10 false *a 1.094,0.333 1.406,0.49 0.313,0.156 10 false *b 2.927,0.302 3.24,0.458 0.313,0.156 10 false IG 2.646,0.094 3.063,0.25 0.417,0.156 10 false ERDF
*a Component without harness connected
(Air Conditioning Control Assembly (recirculation/fresh switch))
*b Indicator


Check that the recirculation/fresh switch LED illuminates.

i.

Apply battery voltage to the air conditioning control assembly (recirculation/fresh switch) and check that the LED illuminates.

OK:
Measurement Condition Switch Position Specified Condition
Battery positive (+) → 3 (IG)
Battery negative (-) → 5 (ERDF)
Recirculation/fresh switch: ON Indicator illuminates


If the result is not as specified, replace the air conditioning control assembly.