When the ignition switch is turned to ON, the battery voltage is applied to terminal IGSW of the ECM. The MREL output signal from ECM causes a current to flow to the coil, closing the contacts of the MAIN relay and supplying power to terminal +B of the ECM.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>REGISTRATION) and initialization (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>INITIALIZATION).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
| *a | Component with harness connected
(ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G130-1 (+B) - C74-7 (E1) | IG ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C74-7 (E1) - Body ground | Always | Below 1 Ω |
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch to ON.
| *a | Component with harness connected
(ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G130-9 (IGSW) - C74-7 (E1) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG (w/o Entry and Start System) |
| NG (w/ Entry and Start System) |
OK
NG (w/o Entry and Start System)
NG (w/ Entry and Start System)
Turn the ignition switch to ON.
| *a | Component with harness connected
(ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G130-8 (MREL) - C74-7 (E1) | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the instrument panel junction block assembly (EFI-MAIN NO. 1 relay).
Click hereEngine / Hybrid System>1KD-FTV ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the harness and connector between the instrument panel junction block (EFI-MAIN NO. 1 relay) and ECM.
Disconnect the instrument panel junction block connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2G-5 - G130-1 (+B) | Always | Below 1 Ω |
| 2P-9 - G130-8 (MREL) | Always | Below 1 Ω |
| 2G-5 or G130-1 (+B) - Body ground | Always | 10 kΩ or higher |
| 2P-9 or G130-8 (MREL) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the instrument panel junction block connector.
Check the harness and connector between the instrument panel junction block (EFI-MAIN NO. 1 relay) and body ground.
Disconnect the instrument panel junction block connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2J-5 - Body ground | Always | Below 1 Ω |
Reconnect the instrument panel junction block connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ignition switch connector.
| *1 | Ignition Switch |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 4 (AM2) - 3 (IG2) | LOCK | 10 kΩ or higher |
| 4 (AM2) - 3 (IG2) | ON | Below 1 Ω |
Reconnect the ignition switch connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the IG2 relay.
Click hereEngine / Hybrid System>1KD-FTV ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Remove the IG2 relay from No. 4 instrument panel relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G130-9 (IGSW) - IG2 Relay terminal 3 | Always | Below 1 Ω |
| G130-9 (IGSW) or IG2 Relay terminal 3 - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the IG2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IG2 relay from No. 4 instrument panel relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| IG2 Relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the certification ECU (smart key ECU assembly) connector.
Remove the IG2 relay from No. 4 instrument panel relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-20 (IG1D) - IG2 Relay terminal 1 | Always | Below 1 Ω |
| IG2 Relay terminal 2 - Body ground | Always | Below 1 Ω |
| G16-20 (IG1D) or IG2 Relay terminal 1 - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the certification ECU (smart key ECU assembly) connector.
Reinstall the IG2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG