Home › Vehicle Interior › DOOR LOCK › WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System)
RM33K0E _58 Vehicle Interior _043547 DOOR LOCK _0222444 WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System) M

DOOR LOCK  WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System)  REGISTRATION  


CAUTION / NOTICE / HINT

HINT:
·

Register a new recognition code when replacing the door control transmitter or the door control receiver.

·

Add mode is used to retain the codes that have already been registered while registering a new recognition code. This mode is used when adding a door control transmitter.

·

Rewrite mode is used to clear all the previously registered codes and register only new recognition codes. This mode is used when exchanging the door control transmitter or the door control receiver with a new one.

·

Confirmation mode is used to confirm how many recognition codes have already been registered before additional registration of a recognition code.

·

Prohibition mode is used to clear all the registered codes and cancel the wireless door lock function. Use this mode when the door control transmitter is lost.

·

All of the steps in the following registration procedure must be performed in sequential order continuously.



PROCEDURE

Hide 1. REGISTRATION OF RECOGNITION CODE

a.

The vehicle should be in the following conditions.

i.

No key is inserted in the ignition key cylinder.


ii.

The driver door is opened (the other doors are closed).


iii.

The driver door is unlocked.


iv.

The driver door window is opened.



b.

Perform the following operations to select the desired mode.

i.

Insert and remove the key from the ignition key cylinder twice within 5 seconds.


ii.

After the above operations, close and open the driver door twice within 40 seconds. Then insert the key into the ignition key cylinder and remove it.


iii.

After the above operations, close and open the driver door twice within 40 seconds. Then insert the key into the ignition key cylinder and close the door.


iv.

Turn the ignition switch from off to ON and back to off at approximately 1 second intervals 1 to 5 times to select a mode (see the illustration). Then remove the key from the ignition key cylinder.

B111914E37
0.094,0.115 4.208,0.354 4.115,0.24 12 false Number of ON-off operations of ignition switch: 0.438,0.802 1.156,1.042 0.719,0.24 10 false Add Mode 3.896,0.813 4.833,1.104 0.938,0.292 10 false Rewrite Mode 1.292,1.25 1.521,1.448 0.229,0.198 10 false T1 4.979,3.24 5.188,3.438 0.208,0.198 10 false T1 5.052,4.417 6.958,4.688 1.906,0.271 10 false T1: Approximately 1 second 1.479,3.24 1.646,3.427 0.167,0.188 10 false T1 1.271,3.24 1.458,3.438 0.188,0.198 10 false T1 5,1.24 5.198,1.448 0.198,0.208 10 false T1 4.771,3.24 4.969,3.438 0.198,0.198 10 false T1 4.792,1.24 4.99,1.438 0.198,0.198 10 false T1 0.229,2.813 1.521,3.052 1.292,0.24 10 false Confirmation Mode 3.958,2.823 4.781,3.094 0.823,0.271 10 false Clear Mode 1.542,0.813 3.25,1.073 1.708,0.26 10 false ON-off operation: Once 5.042,0.813 6.875,1.073 1.833,0.26 10 false ON-off operation: Twice 1.51,2.823 3.458,3.073 1.948,0.25 10 false ON-off operation: 3 times 5.021,2.833 6.927,3.073 1.906,0.24 10 false ON-off operation: 5 times 0.563,1.615 0.833,1.813 0.271,0.198 10 false ON 0.573,3.625 0.844,3.823 0.271,0.198 10 false ON 4.073,1.615 4.344,1.813 0.271,0.198 10 false ON 4.073,3.625 4.344,3.823 0.271,0.198 10 false ON 0.604,3.938 0.875,4.146 0.271,0.208 10 false Off 4.094,3.948 4.365,4.156 0.271,0.208 10 false Off 4.094,1.927 4.365,2.135 0.271,0.208 10 false Off 0.583,1.927 0.854,2.135 0.271,0.208 10 false Off

CAUTION:

If the number of the ON-off operations of the ignition switch is 0, 4 or 6 or more, there will be no response to inform which mode has been selected.



v.

After selecting a mode, the body ECU automatically performs the power door lock-unlock operation within 5 seconds to inform the selected mode (see the illustration).

B111913E31
0.458,1.448 1.125,1.625 0.667,0.177 10 false Add Mode 1.5,1.438 3.594,1.656 2.094,0.219 10 false Lock-unlock operation: Once 0.385,2.24 0.792,2.427 0.406,0.188 10 false Lock 0.271,2.552 0.865,2.75 0.594,0.198 10 false Unlock 1.292,1.927 1.583,2.167 0.292,0.24 10 false T1 3.865,1.448 4.76,1.625 0.896,0.177 10 false Rewrite Mode 5.021,1.438 7.125,1.656 2.104,0.219 10 false Lock-unlock operation: Twice 3.927,2.229 4.365,2.417 0.438,0.188 10 false Lock 3.823,2.552 4.427,2.771 0.604,0.219 10 false Unlock 4.802,1.896 5.083,2.083 0.281,0.188 10 false T1 5,1.896 5.25,2.083 0.25,0.188 10 false T1 0.083,0.073 4.875,0.313 4.792,0.24 12 false Response to selected mode (power door lock operation): 0.083,0.49 6.823,0.875 6.74,0.385 10 false The door control receiver automatically performs power door lock-unlock operations to indicate which mode has been selected. 0.24,3.469 1.438,3.646 1.198,0.177 10 false Confirmation Mode 1.5,3.469 6.844,3.688 5.344,0.219 10 false Lock-unlock operation: The number of registered codes (1 to 4 times or 5 times) 0.417,4.542 0.854,4.719 0.438,0.177 10 false Lock 0.323,4.865 0.917,5.073 0.594,0.208 10 false Unlock 1.375,4.25 1.667,4.5 0.292,0.25 10 false T2 1.771,4.25 2,4.5 0.229,0.25 10 false T2 1.26,6.333 1.5,6.583 0.24,0.25 10 false T1 1.469,6.333 1.75,6.583 0.281,0.25 10 false T1 1.406,3.833 2,4.042 0.594,0.208 10 false 1st Time 2.188,3.833 2.833,4.042 0.646,0.208 10 false 2nd Time 0.438,5.792 1.24,6.052 0.802,0.26 10 false Clear Mode 1.49,5.813 3.76,6.042 2.271,0.229 10 false Lock-unlock operation: 5 times 0.396,6.635 0.844,6.854 0.448,0.219 10 false Lock 0.302,6.969 0.927,7.188 0.625,0.219 10 false Unlock 5.063,6.625 6.958,6.813 1.896,0.188 10 false T1: Approximately 1 second 5.052,6.958 7.052,7.156 2,0.198 10 false T2: Approximately 2 seconds

HINT:
·

In the confirmation mode, the lock-unlock operation will occur once for each recognition code that has been registered. For example, if 2 recognition codes have been registered, the lock-unlock operation will occur 2 times.

·

In the confirmation mode, if no recognition codes have been registered, the lock-unlock operation will occur 5 times.

·

In confirmation mode and prohibition mode, once a lock-unlock operation response has occurred, the registration procedure will end.





c.

Register new recognition codes (Add mode or Rewrite mode):

i.

Within 40 seconds after the add mode or the rewrite mode has been selected, press the lock and unlock switches on the transmitter switch simultaneously for 1.0 to 1.5 seconds. Within 3 seconds after the previous operation, press either one of the switches for more than 1.0 second (Procedure "A").


ii.

Within 5 seconds after the transmitter switch has been released, the lock-unlock operation will be automatically performed once if the registration of the recognition code of the transmitter is completed correctly. In case the lock-unlock operation is performed twice, the registration of recognition code has failed. Perform the registration procedure from the beginning once again (Procedure "B").

B111915E59
0.271,1.427 2.156,1.667 1.885,0.24 10 false Lock-unlock Occurs Once 4.125,1.427 6.031,1.646 1.906,0.219 10 false Lock-unlock Occurs Twice 0.344,2.823 0.771,3 0.427,0.177 10 false Lock 0.24,3.146 0.865,3.354 0.625,0.208 10 false Unlock 1.292,2.479 1.479,2.656 0.188,0.177 10 false T1 4.229,2.823 4.656,3 0.427,0.177 10 false Lock 4.135,3.146 4.76,3.354 0.625,0.208 10 false Unlock 5.167,2.469 5.354,2.646 0.188,0.177 10 false T1 5.375,2.469 5.563,2.646 0.188,0.177 10 false T1 0.094,0.104 3.656,0.385 3.563,0.281 12 false Response to registration completion: 4.979,3.448 6.76,3.635 1.781,0.188 10 false T1: Approximately 1 second 0.198,0.604 6.646,0.969 6.448,0.365 10 false The body ECU automatically performs a power door lock-unlock operation to show whether registration has been completed correctly or not. 0.188,2 3.531,2.365 3.344,0.365 10 false Registration of recognition code has been completed. 4.073,2 6.708,2.406 2.635,0.406 10 false Registration of recognition code has failed.


iii.

If multiple transmitters need to be registered, repeat procedure "A" and "B" within 40 seconds after the previous registration.

HINT:
·

4 recognition codes can be registered at once.

·

If even one of the following conditions is satisfied, the registration mode will end.

·

40 seconds have elapsed after a recognition code has been registered.


·

The driver door is opened.


·

The key is inserted into the ignition key cylinder.


·

4 recognition codes are registered.