Home › Vehicle Interior › DOOR LOCK › WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System)
RM33K0E _58 Vehicle Interior _043547 DOOR LOCK _0222444 WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System) D

DOOR LOCK  WIRELESS DOOR LOCK CONTROL SYSTEM(w/o Smart Entry and Start System)  DIAGNOSIS SYSTEM  


INSPECT BATTERY VOLTAGE


a.

Measure the vehicle battery voltage.

Standard voltage:

11 to 14 V


If the voltage is below 11 V, recharge or replace the battery.



SELF-DIAGNOSTIC MODE (OPERATING IGNITION KEY CYLINDER)


a.

Switch to self-diagnostic mode.

i.

Insert the key into the ignition key cylinder and remove it.


ii.

Within 5 seconds after the key is removed, insert it into the ignition key cylinder and then turn the ignition switch to ON then off 1 time (end in off).


iii.

Within 30 seconds of turning the ignition switch off, perform the following 9 times: Turn the ignition switch to ON then off (end in off).

HINT:

Turning the ignition switch to ON after the procedure above has been completed will end the self-diagnostic mode.


CAUTION:

If the system fails to enter the self-diagnostic mode, the system will return to normal mode.




b.
B220865E58
0.125,0.031 2.229,0.313 2.104,0.281 12 false Interior Light Output: 0.635,1.406 1.063,1.688 0.427,0.281 10 false On 0.646,1.688 0.969,1.948 0.323,0.26 10 false Off 1.552,2.167 1.917,2.5 0.365,0.333 10 false T1 2.146,2.167 2.604,2.604 0.458,0.438 10 false T2 1.979,2.604 3.427,3.042 1.448,0.438 10 false T1: 0.25 seconds 1.979,2.917 3.292,3.313 1.313,0.396 10 false T2: 0.5 seconds 1.802,2.167 2.125,2.51 0.323,0.344 10 false T1

Check that the system has switched to self-diagnostic mode by checking the interior light output pattern.


c.

Check the diagnostic outputs when a door control transmitter switch is pressed. The diagnostic outputs can be checked by the interior light patterns.

B357193E38
0.135,0.104 2.948,0.583 2.813,0.479 12 false Interior Light Output: 0.26,1.021 3.948,1.271 3.688,0.25 10 false Normal Wave (A) (Lock/Unlock/Alarm* Switch): 0.458,2.177 0.917,2.375 0.458,0.198 10 false Off 0.448,1.802 0.906,2 0.458,0.198 10 false On 1.208,2.604 1.667,2.802 0.458,0.198 10 false T1 1.719,2.615 2.177,2.813 0.458,0.198 10 false T2 0.677,3.198 3.823,3.438 3.146,0.24 10 false T1: 0.25 seconds 0.677,3.583 3.823,3.823 3.146,0.24 10 false T2: 0.5 seconds 4.031,0.448 6.323,0.646 2.292,0.198 10 false Unmatching Recognition Code (B): 4.26,0.99 4.719,1.188 0.458,0.198 10 false On 4.281,1.365 4.74,1.563 0.458,0.198 10 false Off 4.917,1.844 6.51,2.094 1.594,0.25 10 false Wave is being received 4.094,2.708 5.688,2.958 1.594,0.25 10 false No Diagnostic Output (C): 4.25,3.188 4.708,3.385 0.458,0.198 10 false Off 0.396,4.354 2.594,4.583 2.198,0.229 10 false *: w/ Alarm Switch

Result
Interior Light Output Suspected Area
A Normal (No malfunction)
B Unmatching register wireless code
C Wave interference or malfunction of a related component