If the engine switch is pressed with the electrical key transmitter sub-assembly in the cabin, the certification ECU (smart key ECU assembly) receives a signal and changes the power source mode.
| Problem Symptom | Data List Item | Active Test Item |
|---|---|---|
| Power source mode does not change to on (IG) but does change to on (ACC) | Power Source Control
·
Power Supply Condition ·
IG Relay Monitor (Inside) ·
IG Relay Monitor (Outside) ·
IG Circuit |
- |
Refer to "SYSTEM DIAGRAM".
When using the GTS with the engine switch off, connect the GTS to the DLC3 and turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and the vehicle begins. Then select the Model Code "KEY REGIST" under manual mode and enter the following menus: Body Electrical / Entry&Start(CAN). While using the GTS, periodically turn a courtesy light switch on and off at intervals of 1.5 seconds or less to maintain communication between the GTS and the vehicle.
The smart entry and start system (for Start Function) uses a multiplex communication system (LIN communication system) and the CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting (Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SMART ENTRY AND START SYSTEM(for Start Function)>HOW TO PROCEED WITH TROUBLESHOOTING). Troubleshoot the smart entry and start system (for Start Function) after confirming that the communication systems are functioning properly.
Make sure that no DTCs are output. If any DTCs are output, proceed to the Diagnostic Trouble Code Chart.
If the smart entry and start system is disabled through the customize function, enable the system before performing troubleshooting.
Before replacing the certification ECU (smart key ECU assembly), refer to the smart entry and start system (for Entry Function) precaution.
Inspect the fuses of circuits related to this system before performing the following procedure.
After completing repairs, confirm that the problem does not occur.
When the cable is disconnected and reconnected to the negative (-) battery terminal, the power source mode returns to the state it was in before the cable was disconnected.
Using the GTS, confirm the output of DTCs for all systems.
No DTCs are output.
Make sure that no DTCs are output. If any DTCs are output, proceed to the Diagnostic Trouble Code Chart.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IG1 NO. 1 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G16 certification ECU (smart key ECU assembly) connector.
Remove the IG1 NO. 1 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-20 (IG1D) - IG1 NO. 1 relay terminal 1 | Always | Below 1 Ω |
| IG1 NO. 1 relay terminal 2 - Body ground | Always | Below 1 Ω |
| G16-20 (IG1D) or IG1 NO. 1 relay terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IG2 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G16 certification ECU (smart key ECU assembly) connector.
Remove the IG2 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-20 (IG1D) - IG2 relay terminal 1 | Always | Below 1 Ω |
| IG2 relay terminal 2 - Body ground | Always | Below 1 Ω |
| G16-20 (IG1D) or IG2 relay terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the G16 certification ECU (smart key ECU assembly) connector.
Install the IG1 NO. 1 relay.
Install the IG2 relay.
Measure the voltage while checking the Data List on the GTS.
| *a | Component with harness connected
(Certification ECU (Smart Key ECU Assembly)) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G16-20 (IG1D) - Body ground | Engine switch off | 1 V or less |
| Engine switch on (ACC) | 1 V or less | |
| Engine switch on (IG) | 9 V or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG