Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM33K0E _58 Vehicle Interior _043555 HEATING / AIR CONDITIONING _0227347 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  Blower Motor Circuit  


DESCRIPTION

The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

E316645E04
5.833,0.75 6.448,0.948 0.615,0.198 10 false BLW 5.552,0.75 6.167,0.948 0.615,0.198 10 false 22 4.188,0.854 4.802,1.052 0.615,0.198 10 false SI 4.469,0.75 5.083,0.948 0.615,0.198 10 false 3 4.135,1.302 4.75,1.5 0.615,0.198 10 false VM 4.469,1.156 5.083,1.354 0.615,0.198 10 false 2 3.094,0.854 3.708,1.052 0.615,0.198 10 false +B 2.865,0.75 3.479,0.948 0.615,0.198 10 false 1 3.094,1.281 3.708,1.479 0.615,0.198 10 false GND 2.875,1.167 3.49,1.365 0.615,0.198 10 false 6 0.729,0.844 2.031,1.073 1.302,0.229 10 false from Battery 2.229,1.01 2.844,1.208 0.615,0.198 10 false HTR 3.063,1.635 3.677,1.833 0.615,0.198 10 false G35 3.042,1.781 4.792,2.021 1.75,0.24 10 false Blower Motor Control 4.479,2.375 5.094,2.573 0.615,0.198 10 false 2 2.854,2.385 3.469,2.583 0.615,0.198 10 false 1 2.75,2.854 3.365,3.052 0.615,0.198 10 false G6 2.75,3.031 5.313,3.219 2.563,0.188 10 false Blower with Fan Motor Sub-assembly 5.521,1.625 6.135,1.823 0.615,0.198 10 false G37 5.521,1.792 7.104,2.24 1.583,0.448 10 false Air Conditioning Amplifier Assembly 4.25,2.375 4.865,2.573 0.615,0.198 10 false B 3.063,2.375 3.677,2.573 0.615,0.198 10 false L

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following procedure.

·

When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>INITIALIZATION



PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2
OK:

Blower with fan motor sub-assembly operates and changes speed.



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY
2.INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY
a.

Remove the blower with fan motor sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>REMOVAL


b.

Inspect the blower with fan motor sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BATTERY AND BODY GROUND)

NG

3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BATTERY AND BODY GROUND)
a.
E293155C04
1.448,0.167 1.969,0.417 0.521,0.25 2.583,1.833 2.333,1.833 2.333,1.833 2.083,1.583 true 0.75,0.917 1,0.917 1,0.917 1.344,1.24 true 1.594,0.219 2.052,0.417 0.458,0.198 10 false G35 0.073,0.073 0.531,0.271 0.458,0.198 10 false *a 0.542,0.833 1,1.031 0.458,0.198 10 false +B 2.625,1.74 3.083,1.938 0.458,0.198 10 false GND
*a Front view of wire harness connector
(to Blower Motor Control)


Disconnect the blower motor control connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G35-6 (GND) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G35-1 (+B) - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the G35 blower motor control connector.


b.

Disconnect the G37 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G35-3 (SI) - G37-22 (BLW) Always Below 1 Ω
G35-3 (SI) or G37-22 (BLW) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BLOWER MOTOR CONTROL AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BLOWER MOTOR CONTROL AND BODY GROUND)
a.

Disconnect the G6 blower with fan motor sub-assembly connector.


b.

Disconnect the G35 blower motor control connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G6-2 (B) - G35-2 (VM) Always Below 1 Ω
G6-1 (L) - Body ground Always Below 1 Ω
G6-2 (B) or G35-2 (VM) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
E313780C03
0.49,0.604 1.021,0.896 0.531,0.292 2.333,1.333 2.083,1.333 2.083,1.333 1.958,1.063 true 0.063,0.083 0.375,0.281 0.313,0.198 10 false *a 2.375,1.24 2.688,1.438 0.313,0.198 10 false SI 2.875,2.833 3.323,3.073 0.448,0.24 10 false GND 0.646,0.656 0.958,0.854 0.313,0.198 10 false G35
*a Component with harness connected
(Blower Motor Control)


Using an oscilloscope, check the waveform.

Item Content
Terminal No. (Symbol) G35-3 (SI) - Body ground
Tool Setting 2 V/DIV., 500 μs/DIV.
Condition
·

Ignition switch ON

·

Blower switch: LO



OK:

Waveform is as shown in the illustration.


HINT:

Waveform varies with the blower level.



Result:
Proceed to
OK
NG



OK

NG

7.CHECK BLOWER MOTOR CONTROL
7.CHECK BLOWER MOTOR CONTROL

b.

Check if the same malfunction recurs when the sonar function is operated.

OK:

Malfunction does not reoccur (returns to normal).



Result:
Proceed to
OK
NG



OK

END (BLOWER MOTOR CONTROL IS DEFECTIVE)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY