The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
Inspect the fuses for circuits related to this system before performing the following procedure.
When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
Connect the GTS to the DLC3.
Turn the ignition switch ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0
Max.: 31 |
- |
| Tester Display |
|---|
| Blower Motor |
Blower with fan motor sub-assembly operates and changes speed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the blower with fan motor sub-assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>REMOVAL
Inspect the blower with fan motor sub-assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Blower Motor Control) |
Disconnect the blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G35-6 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G35-1 (+B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G35 blower motor control connector.
Disconnect the G37 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G35-3 (SI) - G37-22 (BLW) | Always | Below 1 Ω |
| G35-3 (SI) or G37-22 (BLW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G6 blower with fan motor sub-assembly connector.
Disconnect the G35 blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G6-2 (B) - G35-2 (VM) | Always | Below 1 Ω |
| G6-1 (L) - Body ground | Always | Below 1 Ω |
| G6-2 (B) or G35-2 (VM) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Blower Motor Control) |
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G35-3 (SI) - Body ground |
| Tool Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | ·
Ignition switch ON ·
Blower switch: LO |
Waveform is as shown in the illustration.
Waveform varies with the blower level.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the blower motor control.
Check if the same malfunction recurs when the sonar function is operated.
Malfunction does not reoccur (returns to normal).
| Proceed to |
|---|
| OK |
| NG |
OK
NG