Home › General › SPECIFICATIONS › 1KD-FTV BATTERY / CHARGING
RM33K0E _V1 General _043608 SPECIFICATIONS _0203563 1KD-FTV BATTERY / CHARGING F

SPECIFICATIONS  1KD-FTV BATTERY / CHARGING  SERVICE DATA  


CHARGING SYSTEM
Battery Standard Specific Gravity 1.25 to 1.29 at 20°C (68°F)
Standard Voltage 12.6 to 12.8 V at 20°C (68°F)
Fuse Standard Resistance Below 1 Ω
Charging circuit without load Standard Current 10 A or higher
Standard Voltage 12.9 to 14.9 V
Charging circuit with load Standard Current 30 A or higher

GENERATOR BRUSH HOLDER ASSEMBLY
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)

GENERATOR ROTOR ASSEMBLY
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.85 to 2.25 Ω (for 80 A Type)
1.55 to 1.95 Ω (for 90 A Type)
1.65 to 2.05 Ω (for 100 A Type)
Slip ring - Rotor core Always 10 kΩ or higher

Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)