Home › Engine / Hybrid System › 1TR-FE COOLING › THERMOSTAT
RM3250E _51 Engine / Hybrid System _038002 1TR-FE COOLING _0177683 THERMOSTAT G

1TR-FE COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16331A 1.INSPECT THERMOSTAT

A340088

HINT:

The valve opening temperature is inscribed on the thermostat.


a.

Immerse the thermostat in the water, and then gradually heat the water.

CAUTION:
A342307

·

Do not your hands into the water that has been heated for the inspection.

·

Touching the heated water could result in burns.




b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not as specified, replace the thermostat.


c.
A340089C01
2.594,1.74 2.906,1.896 0.313,0.156 10 false *a
*a Valve Lift


Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 95°C (203°F)


If the valve lift is not as specified, replace the thermostat.


d.

Check that the valve is fully closed when the thermostat temperature is below 77°C (171°F).