Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW REGULATOR MOTOR(for Rear Door)
RM3250E _59 Vehicle Exterior _038075 WINDOW / GLASS _0185628 POWER WINDOW REGULATOR MOTOR(for Rear Door) G

WINDOW / GLASS  POWER WINDOW REGULATOR MOTOR(for Rear Door)  INSPECTION  


PROCEDURE

Hide 85720G 1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

a.

w/ Jam Protection Function:

NOTICE:
·

Do not apply positive (+) battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.

·

Perform initialization of the power window system after removing, inspecting or replacing the power window regulator motor assembly LH.



i.
B405917C01
1.531,0.885 0.948,0.771 true 1,1.396 1.49,1.24 true 1.969,1.25 2.5,1.458 true 1.917,0.885 2.479,0.781 true 2.104,4.469 2.417,4.625 0.313,0.156 10 false *b 0.448,0.302 0.76,0.458 0.313,0.156 10 false *a 2.552,1.385 3.167,1.583 0.615,0.198 10 false DOWN 0.75,1.354 1.063,1.552 0.313,0.198 10 false UP 0.813,0.688 0.969,0.885 0.156,0.198 10 false B 2.521,0.698 2.979,0.896 0.458,0.198 10 false GND
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Motor Gear
V100135

Clockwise
V100136

Counterclockwise


Check that the motor gear rotates smoothly as follows.

OK:
Measurement Condition Specified Condition
1.

Connect the positive (+) lead of the battery to terminal 2 (B) and the negative (-) lead to terminal 1 (GND), and hold for 3 sec. or more.

2.

While terminals 2 (B) and 1 (GND) are connected, connect the negative (-) lead of the battery to terminal 10 (UP).

3.

After disconnecting the negative (-) lead of the battery from terminal 10 (UP), connect terminal 10 (UP) to the negative (-) lead of the battery again within 1 sec.


Motor gear rotates clockwise (UP)
1.

Connect the positive (+) lead of the battery to terminal 2 (B) and the negative (-) lead to terminal 1 (GND), and hold for 3 sec. or more.

2.

While terminals 2 (B) and 1 (GND) are connected, connect the negative (-) lead of the battery to terminal 7 (DOWN).

3.

After disconnecting the negative (-) lead of the battery from terminal 7 (DOWN), connect terminal 7 (DOWN) to the negative (-) lead of the battery again within 1 sec.


Motor gear rotates counterclockwise (DOWN)

If the result is not as specified, replace the power window regulator motor assembly LH.



b.
B405920C01
2.073,4.479 2.385,4.635 0.313,0.156 10 false *b 0.375,0.271 0.688,0.427 0.313,0.156 10 false *a
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Motor Gear
V100135

Clockwise
V100136

Counterclockwise


w/o Jam Protection Function:

i.

Apply battery voltage to connector terminals 1 and 2.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.



ii.

Check that the motor gear rotates smoothly as follows.

OK:
Measurement Condition Specified Condition
Battery positive (+) → 1
Battery negative (-) → 2
Motor gear rotates counterclockwise
Battery positive (+) → 2
Battery negative (-) → 1
Motor gear rotates clockwise


If the result is not as specified, replace the power window regulator motor assembly LH.



Hide 85710F 2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

a.

w/ Jam Protection Function:

NOTICE:
·

Do not apply positive (+) battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.

·

Perform initialization of the power window system after removing, inspecting or replacing the power window regulator motor assembly RH.



i.
B405918C01
1.552,0.885 1.031,0.75 true 1.969,1.26 2.479,1.354 true 1.5,1.271 1.063,1.406 true 1.927,0.885 2.448,0.76 true 1.146,4.479 1.458,4.635 0.313,0.156 10 false *b 0.385,0.302 0.698,0.458 0.313,0.156 10 false *a 0.875,0.656 1.031,0.854 0.156,0.198 10 false B 2.552,1.281 3.167,1.479 0.615,0.198 10 false DOWN 0.813,1.344 1.125,1.542 0.313,0.198 10 false UP 2.542,0.667 3,0.865 0.458,0.198 10 false GND
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Motor Gear
V100135

Clockwise
V100136

Counterclockwise


Check that the motor gear rotates smoothly as follows.

OK:
Measurement Condition Specified Condition
1.

Connect the positive (+) lead of the battery to terminal 2 (B) and the negative (-) lead to terminal 1 (GND), and hold for 3 sec. or more.

2.

While terminals 2 (B) and 1 (GND) are connected, connect the negative (-) lead of the battery to terminal 10 (UP).

3.

After disconnecting the negative (-) lead of the battery from terminal 10 (UP), connect terminal 10 (UP) to the negative (-) lead of the battery again within 1 sec.


Motor gear rotates clockwise (UP)
1.

Connect the positive (+) lead of the battery to terminal 2 (B) and the negative (-) lead to terminal 1 (GND), and hold for 3 sec. or more.

2.

While terminals 2 (B) and 1 (GND) are connected, connect the negative (-) lead of the battery to terminal 7 (DOWN).

3.

After disconnecting the negative (-) lead of the battery from terminal 7 (DOWN), connect terminal 7 (DOWN) to the negative (-) lead of the battery again within 1 sec.


Motor gear rotates counterclockwise (DOWN)

If the result is not as specified, replace the power window regulator motor assembly RH.



b.
B405919C04
1.188,4.479 1.5,4.635 0.313,0.156 10 false *b 0.375,0.323 0.688,0.479 0.313,0.156 10 false *a
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Motor Gear
V100135

Clockwise
V100136

Counterclockwise


w/o Jam Protection Function:

i.

Apply battery voltage to connector terminals 1 and 2.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.



ii.

Check that the motor gear rotates smoothly as follows.

OK:
Measurement Condition Specified Condition
Battery positive (+) → 1
Battery negative (-) → 2
Motor gear rotates counterclockwise
Battery positive (+) → 2
Battery negative (-) → 1
Motor gear rotates clockwise


If the result is not as specified, replace the power window regulator motor assembly RH.