Home › Power Source / Network › 1TR-FE BATTERY / CHARGING › GENERATOR(for 80A Type)
RM3250E _57 Power Source / Network _038058 1TR-FE BATTERY / CHARGING _0187520 GENERATOR G

1TR-FE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27415 1.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A226388C07
1.094,0.771 1.219,0.688 false
V100135

Free
V100136

Lock


Hold the center of the generator pulley with clutch, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

If the result is not as specified, replace the generator pulley with clutch.


Hide 27370 2.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A118443C11
1.104,0.531 0.958,0.531 0.958,0.531 0.813,0.698 false 1.146,0.448 1.323,0.615 0.177,0.167 10 false *a
*a Length


Using a vernier caliper, measure the brush length.

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 3.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A251400

Check that the generator rotor bearing is not rough or worn and that it rotates smoothly.

If necessary, replace the generator rotor assembly.


b.

Check the generator rotor assembly for an open circuit.

i.
A236749C07
2.219,0.865 2.552,0.229 2.552,0.229 2.698,0.229 true 2.708,0.135 2.885,0.313 0.177,0.177 10 false *a
*a Slip Ring


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.85 to 2.25 Ω


If the result is not as specified, replace the generator rotor assembly.



c.

Check the generator rotor assembly for a short to ground.

i.
A236750C07
2.354,0.917 2.479,0.427 2.479,0.427 2.563,0.427 false 1.208,0.417 0.958,0.167 0.958,0.167 0.885,0.167 true 2.615,0.344 2.802,0.521 0.188,0.177 10 false *b 0.719,0.104 0.896,0.25 0.177,0.146 10 false *a
*a Rotor Core
*b Slip Ring


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 kΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.

Check each slip ring.

i.

Check that the slip rings are not rough or scored.

If the slip rings are rough or scored, replace the generator rotor assembly.


ii.
A118447C11
0.719,0.594 0.896,0.76 0.177,0.167 10 false *a
*a Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)