Home › Drivetrain › AC60F AUTOMATIC TRANSMISSION / TRANSAXLE › SHIFT LEVER
RM3250E _52 Drivetrain _038031 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0189268 SHIFT LEVER G

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  SHIFT LEVER  INSPECTION  


PROCEDURE

Hide 33550 1.INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/ Smart Entry and Start System)

HINT:

If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.


a.

Inspect wire harness (for LHD):

i.
C324382C02
1.583,1.365 1.583,0.531 1.583,0.531 1.417,0.531 true 2.167,1.417 2.5,0.75 2.5,0.75 2.667,0.75 true 2.135,1.656 2.469,2.156 2.469,2.156 2.635,2.156 true 0.188,0.271 0.5,0.469 0.313,0.198 10 false *a 1.281,0.448 1.594,0.646 0.313,0.198 10 false E 2.729,0.667 3.042,0.865 0.313,0.198 10 false STP 2.677,2.073 2.99,2.271 0.313,0.198 10 false IG
*a Front view of wire harness connector
(to Shift Lock Control ECU)


Disconnect the shift lock control ECU connector from the transmission floor shift assembly.


ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
6 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
12 (IG) - Body ground Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V


If the result is not as specified, repair or replace the shift lock control ECU wire harness.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (E) - Body ground Always Below 1 Ω


If the result is not as specified, repair or replace the shift lock control ECU wire harness.



b.

Inspect wire harness (for RHD):

i.
C326300C01
2.125,1.333 2.438,1.052 2.438,1.052 2.604,1.052 true 2.146,1.656 2.458,1.917 2.458,1.917 2.625,1.917 true 1.135,0.646 1.333,0.646 1.333,0.646 1.625,1.344 true 0.396,0.406 0.708,0.563 0.313,0.156 10 false *a 2.656,0.969 3.115,1.167 0.458,0.198 10 false STP 2.688,1.844 3,2.042 0.313,0.198 10 false IG 1.01,0.573 1.323,0.771 0.313,0.198 10 false E
*a Front view of wire harness connector
(to Shift Lock Control ECU)


Disconnect the shift lock control ECU connector from the transmission floor shift assembly.


ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
6 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
12 (IG) - Body ground Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V


If the result is not as specified, repair or replace the shift lock control ECU wire harness.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (E) - Body ground Always Below 1 Ω


If the result is not as specified, repair or replace the shift lock control ECU wire harness.



c.

Inspect shift lock solenoid:

i.
C197452C42
0.719,1.146 1.292,1.146 true 1.156,1.604 1.344,1.604 1.344,1.604 1.594,1.25 true 2.115,1.125 2.729,1.125 true 2.281,1.594 2.104,1.594 2.104,1.594 1.844,1.25 true 0.063,0.042 0.271,0.229 0.208,0.188 10 false *a 2.813,1.042 2.969,1.24 0.156,0.198 10 false P 2.354,1.51 2.563,1.698 0.208,0.188 10 false E2 0.781,1.531 1.167,1.719 0.385,0.188 10 false SLS- 0.323,1.073 0.74,1.26 0.417,0.188 10 false SLS+
*a Front view of wire harness connector
(to Shift Lock Solenoid)


Disconnect the shift lock solenoid connector from the shift lock control ECU.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
Shift lever not in P Below 1 Ω
1 (SLS+) - 2 (SLS-) Always 112 Ω


·

If the result is not as specified, replace the transmission floor shift assembly.

·

If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.




Hide 33550 2.INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/o Smart Entry and Start System)

HINT:

If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.


a.

Inspect wire harness (for LHD):

i.
C333271C01
2,1.625 2.396,1.625 true 0.979,1.625 1.375,1.625 true 1.219,2.135 1.396,2.135 1.396,2.135 1.594,1.698 true 0.969,1.073 1.146,1.073 1.146,1.073 1.406,1.333 true 2,1.333 2.292,1.063 2.292,1.063 2.427,1.063 true 2.479,0.979 2.938,1.177 0.458,0.198 10 false STP 2.458,1.542 2.917,1.74 0.458,0.198 10 false IG 0.896,2.063 1.354,2.26 0.458,0.198 10 false ACC 0.604,1.542 1.063,1.74 0.458,0.198 10 false KLS+ 0.833,1 1.292,1.198 0.458,0.198 10 false E
*a Front view of wire harness connector
(to Shift Lock Control ECU)


Disconnect the shift lock control ECU connector from the transmission floor shift assembly.


ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
5 (KLS+) - Body ground Ignition switch ACC and shift lever in P Below 1 V
Ignition switch ACC and shift lever not in P 11 to 14 V
6 (ACC) - Body ground Ignition switch ACC 11 to 14 V
Ignition switch off Below 1 V
8 (IG) - Body ground Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V


If the result is not as specified, repair or replace the shift lock control ECU wire harness.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (E) - Body ground Always Below 1 Ω


If the result is not as specified, repair or replace the shift lock control ECU wire harness.



b.

Inspect wire harness (for RHD):

i.
C326301C01
2.021,1.385 2.323,1.052 2.323,1.052 2.479,1.052 true 1.635,1.708 1.5,2.125 1.5,2.125 1.354,2.125 true 2.021,1.646 2.406,1.646 true 1.021,1.646 1.406,1.646 true 1.417,1.385 1.115,1.052 1.115,1.052 0.938,1.052 true 0.406,0.438 0.719,0.594 0.313,0.156 10 false *a 2.542,0.969 3,1.167 0.458,0.198 10 false STP 2.469,1.573 2.781,1.771 0.313,0.198 10 false IG 1.031,2.052 1.49,2.25 0.458,0.198 10 false ACC 0.635,1.573 1.25,1.771 0.615,0.198 10 false KLS+ 0.802,0.979 0.958,1.177 0.156,0.198 10 false E
*a Front view of wire harness connector
(to Shift Lock Control ECU)


Disconnect the shift lock control ECU connector from the transmission floor shift assembly.


ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
5 (KLS+) - Body ground Ignition switch ACC and shift lever in P Below 1 V
Ignition switch ACC and shift lever not in P 11 to 14 V
6 (ACC) - Body ground Ignition switch ACC 11 to 14 V
Ignition switch off Below 1 V
8 (IG) - Body ground Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V


If the result is not as specified, repair or replace the shift lock control ECU wire harness.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (E) - Body ground Always Below 1 Ω


If the result is not as specified, repair or replace the shift lock control ECU wire harness.



c.

Inspect shift lock solenoid:

i.
C197452C42
0.719,1.146 1.292,1.146 true 1.156,1.604 1.344,1.604 1.344,1.604 1.594,1.25 true 2.115,1.125 2.729,1.125 true 2.281,1.594 2.104,1.594 2.104,1.594 1.844,1.25 true 0.063,0.042 0.271,0.229 0.208,0.188 10 false *a 2.813,1.042 2.969,1.24 0.156,0.198 10 false P 2.354,1.51 2.563,1.698 0.208,0.188 10 false E2 0.781,1.531 1.167,1.719 0.385,0.188 10 false SLS- 0.323,1.073 0.74,1.26 0.417,0.188 10 false SLS+
*a Front view of wire harness connector
(to Shift Lock Solenoid)


Disconnect the shift lock solenoid connector from the shift lock control ECU.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
Shift lever not in P Below 1 Ω
1 (SLS+) - 2 (SLS-) Always 112 Ω


·

If the result is not as specified, replace the transmission floor shift assembly.

·

If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.




Hide 3.INSPECT TRANSMISSION CONTROL SWITCH

a.

for LHD:

i.
C324384C01
0.906,1.49 1.24,1.49 true 0.958,1.969 1.125,1.969 1.125,1.969 1.458,1.552 true 1.719,1.563 1.719,1.979 true 2.396,2.031 2.229,2.031 2.229,2.031 1.979,1.531 true 2.198,1.5 2.531,1.5 true 0.208,0.292 0.521,0.49 0.313,0.198 10 false *a 0.781,1.438 1.094,1.635 0.313,0.198 10 false S 0.781,1.906 1.094,2.104 0.313,0.198 10 false IG 1.573,2.031 2.052,2.229 0.479,0.198 10 false SFTU 2.458,1.969 2.771,2.167 0.313,0.198 10 false E 2.583,1.427 3.063,1.625 0.479,0.198 10 false SFTD
*a Component without harness connected
(Transmission Control Switch)


Disconnect the transmission control switch connector from the transmission floor shift assembly.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
Shift lever not in S, "+" or "-" 10 kΩ or higher
3 (SFTU) - 2 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
Shift lever not held in "+" (Up-shift) 10 kΩ or higher
1 (SFTD) - 2 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
Shift lever not held in "-" (Down-shift) 10 kΩ or higher


If the result is not as specified, replace the transmission floor shift assembly.



b.

for RHD:

i.
C326302C01
2.198,1.49 2.646,1.49 true 1.927,1.563 2.104,1.875 2.104,1.875 2.271,1.875 true 1.719,1.563 2.01,2.104 2.01,2.104 2.177,2.104 true 0.771,1.49 1.219,1.49 true 1.198,1.896 1.365,1.896 1.365,1.896 1.49,1.573 true 0.385,0.396 0.698,0.552 0.313,0.156 10 false *a 2.24,2.021 2.854,2.219 0.615,0.198 10 false SFTD 2.698,1.406 3.313,1.604 0.615,0.198 10 false SFTU 2.344,1.792 2.5,1.99 0.156,0.198 10 false E 0.635,1.417 0.792,1.615 0.156,0.198 10 false S 1.021,1.823 1.333,2.021 0.313,0.198 10 false IG
*a Component without harness connected
(Transmission Control Switch)


Disconnect the transmission control switch connector from the transmission floor shift assembly.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
Shift lever not in S, "+" or "-" 10 kΩ or higher
1 (SFTU) - 2 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
Shift lever not held in "+" (Up-shift) 10 kΩ or higher
3 (SFTD) - 2 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
Shift lever not held in "-" (Down-shift) 10 kΩ or higher


If the result is not as specified, replace the transmission floor shift assembly.