Home › Engine / Hybrid System › 1KD-FTV ENGINE CONTROL › MANIFOLD ABSOLUTE PRESSURE SENSOR
RM3250E _51 Engine / Hybrid System _037990 1KD-FTV ENGINE CONTROL _0189621 MANIFOLD ABSOLUTE PRESSURE SENSOR G

1KD-FTV ENGINE CONTROL  MANIFOLD ABSOLUTE PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 89421C 1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR

a.

Inspect the power source voltage.

i.

Disconnect the manifold absolute pressure sensor connector.


ii.
A110326C01
2.042,1.177 1.604,0.719 1.604,0.719 1.469,0.719 true 2.167,1.177 2.615,0.729 2.615,0.729 2.76,0.729 true 2.802,0.646 3.406,0.833 0.604,0.188 10 true 3 VC (+) 0.948,0.604 1.438,0.823 0.49,0.219 10 true 1 E (-) 0.031,0.031 0.219,0.198 0.188,0.167 10 true *a
*a Front view of wire harness connector
(to Manifold Absolute Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
3 VC (+) - 1 E (-) Ignition switch ON 4.75 to 5.25 V


If the result is not as specified, inspect the wire harness or ECM (Click here Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>TERMINALS OF ECM).


iii.

Connect the manifold absolute pressure sensor connector.



b.
A301621C08
0.625,0.615 1.01,0.885 0.385,0.271 1.26,0.604 1.646,0.875 0.385,0.271 1.417,3.406 1.417,3.76 true 2.823,3.417 2.823,3.771 true 0.083,0.063 0.396,0.219 0.313,0.156 10 false *a 0.677,0.688 1.01,0.854 0.333,0.167 10 false C55 1.333,0.677 1.667,0.844 0.333,0.167 10 false C56 1.292,3.792 1.677,3.99 0.385,0.198 10 false E2 (-) 2.615,3.792 3.125,3.969 0.51,0.177 10 false PIM (+)
*a Component with harness connected
(ECM)


Check the power supply.

i.

Turn the ignition switch to ON.


ii.

Disconnect the vacuum hose from the manifold absolute pressure sensor.


iii.
A110328C01
1.219,0.792 0.885,0.792 false 1.25,0.708 1.448,0.875 0.198,0.167 10 true *1
*1 Vacuum Pump
V100135

Vacuum


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C56-28 (PIM +) - C55-28 (E2 -) 13.3 kPa (100 mmHg, 3.94 in.Hg) 0.0 to 0.3 V
26.6 kPa (199 mmHg, 7.85 in.Hg) 0.2 to 0.6 V
40 kPa (300 mmHg, 11.81 in.Hg) 0.4 to 0.8 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.


iv.
A110330C01
0.646,1 0.781,1 0.781,1 0.906,1.146 true 0.344,0.927 0.688,1.073 0.344,0.146 10 true SST
V100135

Pressure


Using SST, measure the voltage according to the value(s) in the table below.

SST
09992-00242  

Standard Voltage:
Tester Connection Condition Specified Condition
C56-28 (PIM +) - C55-28 (E2) 19.6 kPa (0.20 kgf/cm2, 2.84 psi) 0.05 to 0.3 V
39.2 kPa (0.40 kgf/cm2, 5.68 psi) 0.25 to 0.55 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi) 0.45 to 0.75 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi) 0.65 to 0.95 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi) 0.9 to 1.2 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.