Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY
RM3250E _52 Drivetrain _038029 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0193342 VALVE BODY ASSEMBLY G

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35230C 1.INSPECT SHIFT SOLENOID VALVE SR

a.
C214329C08
0.094,0.063 0.344,0.26 0.25,0.198 10 false *a 1.76,0.281 1.948,0.479 0.188,0.198 10 false (-) 2.417,0.281 2.667,0.479 0.25,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SR)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve SR and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise


If the result is not as specified, replace the shift solenoid valve SR.


Hide 35280A 2.INSPECT SHIFT SOLENOID VALVE SLU

a.
C209928C34
1.75,0.99 2.188,0.417 true 1.49,0.99 1.031,0.417 true 1.75,2.969 2.198,2.385 true 1.479,2.979 1.031,2.396 true 0.083,0.063 0.396,0.26 0.313,0.198 10 false *a 2.219,0.26 2.385,0.458 0.167,0.198 10 false 1 0.927,0.26 1.094,0.458 0.167,0.198 10 false 2 2.229,2.24 2.396,2.438 0.167,0.198 10 false 1 0.927,2.24 1.094,2.438 0.167,0.198 10 false 2 1.896,3.948 2.094,4.146 0.198,0.198 10 false (-) 1.177,3.948 1.396,4.146 0.219,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SLU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve SLU and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the shift solenoid valve SLU.


Hide 35280A 3.INSPECT SHIFT SOLENOID VALVE SLT

HINT:

Refer to Inspect Shift Solenoid Valve SLU.


Hide 35210A 4.INSPECT SHIFT SOLENOID VALVE SL1

a.
C197715C23
1.75,1 2.198,0.417 true 1.49,1 1.031,0.417 true 1.74,2.99 2.188,2.396 true 1.49,2.99 1.031,2.396 true 0.094,0.063 0.406,0.26 0.313,0.198 10 false *a 2.229,0.25 2.396,0.448 0.167,0.198 10 false 1 0.927,0.25 1.094,0.448 0.167,0.198 10 false 2 2.229,2.24 2.396,2.438 0.167,0.198 10 false 1 0.927,2.24 1.094,2.438 0.167,0.198 10 false 2 1.885,3.948 2.115,4.146 0.229,0.198 10 false (+) 1.219,3.958 1.448,4.156 0.229,0.198 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve SL1)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve SL1 and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the shift solenoid valve SL1.


Hide 35210C 5.INSPECT SHIFT SOLENOID VALVE SL2

HINT:

Refer to Inspect Shift Solenoid Valve SL1.


Hide 35240E 6.INSPECT SHIFT SOLENOID VALVE S1

a.
C214327C07
0.094,0.073 0.333,0.271 0.24,0.198 10 false *a 2.5,0.292 2.76,0.469 0.26,0.177 10 false (+) 3.188,0.292 3.396,0.479 0.208,0.188 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve S1)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise


If the result is not as specified, replace the shift solenoid valve.


Hide 35250E 7.INSPECT SHIFT SOLENOID VALVE S2

a.
C214328C06
0.094,0.083 0.344,0.281 0.25,0.198 10 false *a 1.802,0.271 2,0.469 0.198,0.198 10 false (-) 2.469,0.271 2.698,0.469 0.229,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve S2)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S2 connector

·

Battery negative (-) → Shift solenoid valve S2 body


Valve moves and makes an operating noise


If the result is not as specified, replace the shift solenoid valve.