RM3250E
_V1
General
_038082
SPECIFICATIONS
_0176430
2GD-FTV COOLING
F
SPECIFICATIONS 2GD-FTV COOLING SERVICE DATA
COOLANT
| Item
|
Specified Condition
|
| w/o Heater
|
for Manual Transmission
|
w/o DPF
|
8.0 liters (8.5 US qts, 7.0 Imp. qts)
|
| w/ Heater
|
for Manual Transmission
|
w/o DPF
|
8.6 liters (9.1 US qts, 7.6 Imp. qts)
|
| w/ DPF
|
8.7 liters (9.2 US qts, 7.7 Imp. qts)
|
| for Automatic Transmission
|
w/o DPF
|
9.1 liters (9.6 US qts, 8.0 Imp. qts)
|
| w/ DPF
|
9.2 liters (9.7 US qts, 8.1 Imp. qts)
|
| w/ Viscous Heater
|
for Manual Transmission
|
w/o DPF
|
8.9 liters (9.4 US qts, 7.8 Imp. qts)
|
| w/ DPF
|
9.1 liters (9.6 US qts, 8.0 Imp. qts)
|
| for Automatic Transmission
|
w/ DPF
|
9.6 liters (10.1 US qts, 8.4 Imp. qts)
|
THERMOSTAT
| Thermostat
|
Valve opening temperature
|
80 to 84 °C (176 to 183 °F)
|
| Valve lift
|
10 mm (0.394 in.) or more at 95°C (203°F)
|
RADIATOR
| Reservoir cap
|
Standard Judgment Criterion
|
Standard value
(for brand-new cap)
|
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
|
Minimum standard value
(for used cap)
|
79 kPa (0.8 kgf/cm2, 11.4 psi)
|