Home › General › SPECIFICATIONS › 2GD-FTV EMISSION CONTROL › 2015.06–2016.08
RM3250E _V1 General _038082 SPECIFICATIONS _0200011 2GD-FTV EMISSION CONTROL F

SPECIFICATIONS  2GD-FTV EMISSION CONTROL  SERVICE DATA  


NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 1 MΩ or higher

EXHAUST GAS TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 89.3 to 159.8 kΩ

EXHAUST FUEL ADDITION INJECTOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 7.1 to 7.9 Ω