Home › Power Source / Network › 5L-E BATTERY / CHARGING › GENERATOR › from 2016.01
RM3250E _57 Power Source / Network _049929 5L-E BATTERY / CHARGING _0240671 GENERATOR G

5L-E BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27370 1.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A113754C11
0.688,0.677 0.865,0.844 0.177,0.167 10 false *a
*a Length


Using a vernier caliper, measure the brush length.

Standard length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum length:

4.5 mm (0.177 in.)


If the length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 2.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A079306

Check that the generator rotor bearing is not rough or worn and that it rotates smoothly.

If necessary, replace the generator rotor assembly.


b.
B012264C20
0.354,1.146 0.479,0.146 0.479,0.146 0.469,1.052 true 0.479,0.156 1.531,0.156 true 1.583,0.063 1.813,0.229 0.229,0.167 10 false *a
*a Slip Ring


Check the generator rotor assembly for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.1 to 2.5 Ω


If the result is not as specified, replace the generator rotor assembly.



c.
B012265C18
1.625,0.458 1.542,0.458 1.542,0.458 1.313,0.76 true 0.448,1.229 0.823,1.594 0.823,1.594 1.052,1.594 false 1.698,0.323 1.854,0.49 0.156,0.167 10 false *a 1.104,1.51 1.281,1.667 0.177,0.156 10 false *b
*a Rotor Core
*b Slip Ring


Check if the generator rotor assembly is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Rotor core - Slip ring Always 10 MΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.

Check each slip ring.

i.

Check that the slip rings are not rough or scored.

If the slip rings are rough or scored, replace the generator rotor assembly.


ii.
A220278C03
0.531,0.583 0.844,0.74 0.313,0.156 10 false *a
*a Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.



Hide 27311 3.INSPECT GENERATOR DRIVE END FRAME

a.
A220279C02
2.604,1.042 2.833,0.25 2.833,0.25 2.917,0.25 true 3,0.167 3.313,0.323 0.313,0.156 10 false *a
*a Coil Lead


Check the stator for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Coil lead Always Below 1 Ω


If the result is not as specified, replace the generator assembly.



b.
A220280C02
2.49,0.448 2.833,0.167 2.833,0.167 2.917,0.167 true 1,1.417 1.083,1.417 1.083,1.417 1.302,1.542 true 0.813,1.333 1.125,1.49 0.313,0.156 10 false *1 2.979,0.083 3.292,0.24 0.313,0.156 10 false *a
*1 Generator Drive End Frame
*a Coil Lead


Check the stator for a short circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Generator drive end frame Always 10 MΩ or higher


If the result is not as specified, replace the generator assembly.



c.

Inspect the generator drive end frame bearing.

i.

Check that the generator drive end frame bearing is not rough or worn.

If necessary, replace the generator assembly.



Hide 27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER

a.
A220282C02
1.25,0.75 1.333,0.75 1.333,0.75 1.875,0.958 true 2.177,1.125 2.583,0.667 2.583,0.667 2.667,0.667 true 1.042,0.656 1.354,0.813 0.313,0.156 10 false *a 2.729,0.563 3.042,0.719 0.313,0.156 10 false *b
*a Terminal B
*b Rectifier Terminal


Check the positive terminal of the generator holder with rectifier.

i.

Using an ohmmeter, connect one tester probe to the terminal B and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal B - one polarity Always Below 1 Ω
Terminal B - other polarity Always 10 MΩ or higher


If the result is not as specified, replace the generator holder with rectifier.



b.
A220283C02
1.594,1.396 1.083,0.417 1.083,0.417 1,0.417 true 0.823,0.323 1.135,0.479 0.313,0.156 10 false *a
*a Negative (-) Terminal


Check the negative (-) terminal of the generator holder with rectifier.

i.

Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Negative (-) terminal - one polarity Always Below 1 Ω
Negative (-) terminal - other polarity Always 10 MΩ or higher


If the result is not as specified, replace the generator holder with rectifier.



Hide 27700A 5.INSPECT GENERATOR REGULATOR ASSEMBLY

a.
A220284C03
1.677,0.99 1.083,1.583 1.083,1.583 1,1.583 true 2.25,1.292 2.5,1.833 2.5,1.833 2.583,1.833 true 0.792,1.49 1.104,1.646 0.313,0.156 10 false *a 2.646,1.74 2.958,1.896 0.313,0.156 10 false *b
*a Terminal F
*b Terminal B


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal F - Terminal B Always Below 1 Ω or higher than 10 MΩ


If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the regulator, one of the above values is output.

When the leads are reversed, the reading changes to the other value.



b.
A220285C03
0.75,1.01 0.917,1.583 0.917,1.583 1,1.583 true 1.813,1.031 2.167,1.667 2.167,1.667 2.25,1.667 true 2.323,1.563 2.635,1.719 0.313,0.156 10 false *a 1.073,1.479 1.385,1.635 0.313,0.156 10 false *b
*a Terminal F
*b Terminal E


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal F - Terminal E Always Below 1 Ω or higher than 10 MΩ


If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the regulator, one of the above values is output.

When the leads are reversed, the reading changes to the other value.