Home › Power Source / Network › 5L-E BATTERY / CHARGING › GENERATOR › from 2016.01
RM3250E _57 Power Source / Network _049929 5L-E BATTERY / CHARGING _0240671 GENERATOR A

5L-E BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 16361A 3.REMOVE FAN AND GENERATOR V BELT

Hide 4.REMOVE COMPRESSOR ASSEMBLY WITH MAGNETIC CLUTCH

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A378528

Remove the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator connector.


d.
A378529

Disconnect the vacuum pump hose.


e.

Remove the union bolt to disconnect the vacuum pump oil inlet hose and remove the 2 gaskets.


f.

Detach the vacuum pump oil inlet hose from the cord clip.


g.

Disconnect the vacuum pump oil outlet hose.


h.
A378530

Remove the 2 bolts and generator assembly.