Home › Engine / Hybrid System › 2GD-FTV EMISSION CONTROL › UREA INJECTOR › from 2016.03
RM3250E _51 Engine / Hybrid System _038008 2GD-FTV EMISSION CONTROL _0262567 UREA INJECTOR A

2GD-FTV EMISSION CONTROL  UREA INJECTOR  INSTALLATION  


PROCEDURE

Hide 23203A 1.INSTALL UREA INJECTOR SET

a.

Clean the surfaces of the urea injector set and front exhaust pipe assembly.


b.

Install a new gasket and the urea injector set to the front exhaust pipe assembly with 2 new nuts.

Torque:
30 N*m (306 kgf*cm, 22 ft.*lbf)


c.

Connect the connector to the urea injector set.


Hide 77840A 2.CONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:
·

Check for dirt or mud on the urea injector set and around the urea tube connector before connection. Clean if necessary.

·

In order to prevent the urea injector set interior set portion from drying, perform installation and removal work as quickly as possible.



a.

Connect the urea tube with heater assembly to the urea injector set.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea injector set, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea injector set with water to remove all solidified urea solution (white solids).


iii.
A379843C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the urea injector set. Push the urea tube connector into the urea injector set until the urea tube connector makes a "click" sound.


iv.

After connecting the urea injector set and the urea tube connector, check that the urea injector set and urea tube connector are securely connected by trying to pull them apart.


v.

Attach the lock claws to the urea tube connector by pushing down on the cover.