83910G
1.INSPECT CLOCK ASSEMBLY (Hazard Warning Switch)
Inspect the clock assembly (hazard warning switch).
| *a | Component without harness connected
Clock Assembly (Hazard Warning Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H3-3 (TB) - H3-1 (E) | Hazard warning switch off | 10 kΩ or higher |
| Hazard warning switch on | Below 1 Ω |
If the result is not as specified, replace the clock assembly (hazard warning switch).
| *a | Component without harness connected
Clock Assembly (Hazard Warning Switch) |
Check the illumination.
Apply battery voltage to the connector and check the illumination conditions.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → H3-9 (ILL+)
Battery negative (-) → H3-6 (ILL-) |
Illuminates |
If the result is not as specified, replace the clock assembly (hazard warning switch).