Home › Engine / Hybrid System › 2TR-FE EMISSION CONTROL › CANISTER
RM33J0E _51 Engine / Hybrid System _038457 2TR-FE EMISSION CONTROL _0189938 CANISTER G

2TR-FE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 77704 1.INSPECT CANISTER

a.

Visually check the canister.

i.

Visually check the canister for cracks or damage.

If cracks or damage are found, replace the canister.



b.

Inspect the ventilation of the canister.

i.
A350700C01
2.813,0.344 2.958,0.188 2.958,0.188 3.104,0.188 false 0.708,1.406 0.906,1.406 0.906,1.406 1.302,0.719 true 1.625,0.771 1.938,0.583 1.938,0.583 2.073,0.583 true 1.333,0.448 1.802,0.26 1.802,0.26 1.958,0.26 true 2.104,0.49 2.313,0.698 0.208,0.208 10 false *a 0.521,1.302 0.708,1.49 0.188,0.188 10 false *b 2,0.167 2.208,0.354 0.208,0.188 10 false *c 3.135,0.083 3.333,0.292 0.198,0.208 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Vacuum Pump


Using a vacuum pump, apply vacuum (1.96 kPa (15 mmHg, 0.579 in. Hg)) to the port (A) with the port (B) and port (C) closed.

OK:

Air does not flow.



ii.
A350701C01
0.729,1.448 0.875,1.448 0.875,1.448 1.26,0.719 true 1.625,0.771 1.917,0.583 1.917,0.583 2.083,0.583 true 2.802,0.333 2.927,0.188 2.927,0.188 3.063,0.188 false 1.354,0.469 1.781,0.281 1.781,0.281 1.938,0.281 true 2.115,0.49 2.302,0.698 0.188,0.208 10 false *a 0.563,1.344 0.771,1.542 0.208,0.198 10 false *b 1.969,0.177 2.156,0.375 0.188,0.198 10 false *c 3.094,0.094 3.302,0.313 0.208,0.219 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Vacuum Pump


Using a vacuum pump, apply vacuum (1.96 kPa (15 mmHg, 0.579 in. Hg)) to the port (A) with the port (C) closed.

OK:

Air is sucked into the port (B).



iii.
A350702C01
0.792,0.375 0.958,0.375 0.958,0.375 1.417,0.583 true 0.833,1.583 1.042,1.583 1.042,1.583 1.354,0.875 true 1.802,0.948 2.26,0.885 2.26,0.885 2.51,0.885 true 2.542,0.792 2.74,1 0.198,0.208 10 false *a 0.646,1.49 0.865,1.688 0.219,0.198 10 false *b 0.604,0.271 0.792,0.469 0.188,0.198 10 false *c 2.521,1.188 2.74,1.385 0.219,0.198 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Close the port (C) and apply compressed air (4.41 kPa (0.04 kgf/cm2, 0.6 psi)) to the port (A).

OK:

Air flows out from the port (B).



iv.
A350703C01
0.958,0.615 1.177,0.615 1.177,0.615 1.531,0.917 true 1.656,0.615 1.979,0.427 1.979,0.427 2.146,0.427 true 1.969,0.99 2.25,0.802 2.25,0.802 2.438,0.802 true 2.469,0.698 2.667,0.906 0.198,0.208 10 false *a 0.771,0.51 0.958,0.708 0.188,0.198 10 false *b 2.188,0.323 2.375,0.531 0.188,0.208 10 false *c 2.698,1.208 2.885,1.417 0.188,0.208 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Apply compressed air (4.41 kPa (0.04 kgf/cm2, 0.6 psi)) to the port (A).

OK:

Air flows out from the port (B) and port (C).