Home › Engine / Hybrid System › 2TR-FE EMISSION CONTROL › PURGE VALVE
RM33J0E _51 Engine / Hybrid System _038457 2TR-FE EMISSION CONTROL _0189939 PURGE VALVE G

2TR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 17650G 1.INSPECT PURGE VSV

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω
1 - Body ground Always 10 MΩ or higher
2 - Body ground


HINT:

When measuring the coil resistance, make sure that the surface temperature of the purge VSV is 20°C (68°F).


If the result is not as specified, replace the purge VSV.


b.
A346869C01
1.771,1.094 2.094,0.833 2.094,0.833 2.271,0.833 true 2.219,1.385 2.396,1.698 2.396,1.698 2.573,1.698 true 2.51,0.042 2.708,0.25 0.198,0.208 10 false *a 2.333,0.74 2.531,0.938 0.198,0.198 10 false *b 2.615,1.583 2.802,1.771 0.188,0.188 10 false *c
*a Air
*b Port E
*c Port F


Check operation of the purge VSV.

i.

Check that air does not flow from port E to port F.


ii.
A346870C01
0.667,1.448 0.813,1.448 0.813,1.448 1.188,1.708 true 0.781,2.969 0.781,2.51 true 1.542,1.625 1.542,1.104 1.542,1.104 1.646,1.104 true 1.656,1.677 2.042,1.917 2.042,1.917 2.146,1.917 true 1.813,0.719 2.01,0.906 0.198,0.188 10 false *a 0.49,1.365 0.688,1.552 0.198,0.188 10 false *b 0.719,2.99 0.906,3.177 0.188,0.188 10 false *c 2.188,1.833 2.313,2.01 0.125,0.177 10 false 2 1.688,1.01 1.813,1.188 0.125,0.177 10 false 1
*a Air
*b Port E
*c Port F


Apply battery voltage across terminals 1 and 2.


iii.

Check that air flows from port E to port F.

If the result is not as specified, replace the purge VSV.