Home › Engine / Hybrid System › 2TR-FE FUEL › FUEL PUMP
RM33J0E _51 Engine / Hybrid System _038456 2TR-FE FUEL _0189947 FUEL PUMP G

2TR-FE FUEL  FUEL PUMP  INSPECTION  


PROCEDURE

Hide 23220A 1.INSPECT FUEL PUMP

a.

Inspect the resistance of the fuel pump.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω


If the result is not as specified, replace the fuel pump.



b.
A344555C01
1.875,0.573 2.156,0.198 2.156,0.198 2.375,0.198 true 1.531,0.594 1.24,0.219 1.24,0.219 0.979,0.219 true 0.042,0.031 0.354,0.188 0.313,0.156 10 false *a 2.427,0.115 2.573,0.313 0.146,0.198 10 false 1 0.833,0.146 0.979,0.344 0.146,0.198 10 false 2
*a Component without harness connected
(Fuel Pump)


Inspect the operation of the fuel pump.

i.

Connect the battery positive (+) lead to terminal 1 of the connector, and the negative (-) lead to terminal 2. Check that the fuel pump operates.

NOTICE:
·

These tests must be performed within 10 seconds to prevent the coil from burning out.


·

Keep the fuel pump as far away from the battery as possible.


·

Always turn the voltage on and off on the battery side, not the fuel pump side.



If the result is not as specified, replace the fuel pump.