55900
1.INSPECT AIR CONDITIONING CONTROL ASSEMBLY (for Manual Cooler System)
Check the switch function.
| *a | Component without harness connected
(Air Conditioning Control Assembly (Window Defogger Switch)) |
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 7 (RDEF) - 9 (ERDF) | Push (ON) | Below 1 Ω |
| 7 (RDEF) - 9 (ERDF) | Not push (OFF) | 10 kΩ or higher |
If the result is not as specified, replace the air conditioning control assembly (window defogger switch).
| *a | Component without harness connected
(Air Conditioning Control Assembly (Window Defogger Switch)) |
| *b | Indicator |
Check that the LED illuminates.
Apply battery voltage to the air conditioning control assembly (window defogger switch) and check that the LED illuminates.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 1 (ILL+)
Battery negative (-) → 10 (ILL-) |
LED illuminates |
If the result is not as specified, replace the air conditioning control assembly (window defogger switch).
Apply battery voltage to the air conditioning control assembly (window defogger switch) and check that the indicator.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → 6 (IG)
Battery negative (-) → 9 (ERDF) |
Push (ON) | Indicator illuminates |
| Not push (OFF) | Indicator not illuminates |
If the result is not as specified, replace the air conditioning control assembly (window defogger switch).