Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM33J0E _58 Vehicle Interior _038504 HEATING / AIR CONDITIONING _0193639 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler thermistor (room temperature sensor) Min.: -6.50°C (-20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler thermistor (room temperature sensor) system malfunction:
·

When open circuit: -6.50°C (-20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Thermistor assembly (ambient temperature sensor) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly (ambient temperature sensor) system malfunction:
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- Air conditioning amplifier assembly malfunction
Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor (evaporator temperature sensor) system malfunction:
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Solar Sensor (D Side) Cooler thermistor (solar sensor) 0 to 255 Cooler thermistor (solar sensor) value increases as brightness increases Cooler thermistor (solar sensor) malfunction:
·

When open circuit: 0

·

When short circuit: 255


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

ECD system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower with fan motor sub-assembly system malfunction
Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly (rear mode) target pulse Min.: 128
Max.: 383
FACE: 253 (pulse)
B/L: 264 (pulse)
SHUT: 276 (pulse)
·

Displayed between 253 and 276 pulse

·

No. 2 air conditioning radiator damper servo sub-assembly (rear mode) system malfunction

·

w/ Rear Face Register


Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly (rear mode) actual pulse Min.: 128
Max.: 383
FACE: 253 (pulse)
B/L: 264 (pulse)
SHUT: 276 (pulse)
·

Displayed between 253 and 276 pulse

·

No. 2 air conditioning radiator damper servo sub-assembly (rear mode) system malfunction

·

w/ Rear Face Register


Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (front side air mix) target pulse Min.: 128
Max.: 383
for LHD:

MAX. COLD: 257 (pulse)

MAX. HOT: 165 (pulse)


for RHD:

MAX. COLD: 255 (pulse)

MAX. HOT: 347 (pulse)


·

Displayed between 165 and 257 pulse (for LHD)

·

Displayed between 255 and 347 pulse (for RHD)

·

No. 1 air conditioning radiator damper servo sub-assembly (front side air mix) system malfunction


Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (front side air mix) actual pulse Min.: 128
Max.: 383
for LHD:

MAX. COLD: 257 (pulse)

MAX. HOT: 165 (pulse)


for RHD:

MAX. COLD: 255 (pulse)

MAX. HOT: 347 (pulse)


·

Displayed between 165 and 257 pulse (for LHD)

·

Displayed between 255 and 347 pulse (for RHD)

·

No. 1 air conditioning radiator damper servo sub-assembly (front side air mix) system malfunction


Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (front mode) target pulse Min.: 128
Max.: 383
for LHD:

FACE: 257 (pulse)

FACE1: 257 (pulse)

FACE2: 257 (pulse)

B/L: 223 (pulse)

B/L2: 223 (pulse)

FOOT-R: 195 (pulse)

FOOT-M: 195 (pulse)

FOOT: 195 (pulse)

FOOT-D: 189 (pulse)

FOOT-0: 195 (pulse)

FOOT F: 195 (pulse)

F/D: 175 (pulse)

DEF: 143 (pulse)


for RHD:

FACE: 255 (pulse)

FACE1: 255 (pulse)

FACE2: 255 (pulse)

B/L: 271 (pulse)

B/L2: 271 (pulse)

FOOT-R: 299 (pulse)

FOOT-M: 299 (pulse)

FOOT: 299 (pulse)

FOOT-D: 307 (pulse)

FOOT-0: 299 (pulse)

FOOT F: 317 (pulse)

F/D: 337 (pulse)

DEF: 369 (pulse)


·

Displayed between 143 and 257 pulse (for LHD)

·

Displayed between 255 and 369 pulse (for RHD)

·

No. 1 air conditioning radiator damper servo sub-assembly (front mode) system malfunction


Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (front mode) actual pulse Min.: 128
Max.: 383
for LHD:

FACE: 257 (pulse)

FACE1: 257 (pulse)

FACE2: 257 (pulse)

B/L: 223 (pulse)

B/L2: 223 (pulse)

FOOT-R: 195 (pulse)

FOOT-M: 195 (pulse)

FOOT: 195 (pulse)

FOOT-D: 189 (pulse)

FOOT-0: 195 (pulse)

FOOT F: 195 (pulse)

F/D: 175 (pulse)

DEF: 143 (pulse)


for RHD:

FACE: 255 (pulse)

FACE1: 255 (pulse)

FACE2: 255 (pulse)

B/L: 271 (pulse)

B/L2: 271 (pulse)

FOOT-R: 299 (pulse)

FOOT-M: 299 (pulse)

FOOT: 299 (pulse)

FOOT-D: 307 (pulse)

FOOT-0: 299 (pulse)

FOOT F: 317 (pulse)

F/D: 337 (pulse)

DEF: 369 (pulse)


·

Displayed between 143 and 257 pulse (for LHD)

·

Displayed between 255 and 369 pulse (for RHD)

·

No. 1 air conditioning radiator damper servo sub-assembly (front mode) system malfunction


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (recirculation) target pulse Min.: 128
Max.: 383
Recirculation: 258 (pulse)
Fresh: 235 (pulse)
No. 1 blower damper servo sub-assembly (recirculation) system malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly (recirculation) actual pulse Min.: 128
Max.: 383
Recirculation: 258 (pulse)
Fresh: 235 (pulse)
No. 1 blower damper servo sub-assembly (recirculation) system malfunction
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Evaporator Control Evaporator control Auto or Manual Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/DEF Auto Mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/DEF Auto blower speed increase ON or OFF Customized value displayed -
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Front side set temperature Min.: MAX COLD
Max.: MAX HOT
Front side set temperature displayed
·

LIN communication system malfunction

·

Air conditioning control assembly system malfunction


Outside Air Mode Auto Switch Function Switches ON/OFF the function to switch the suction opening to the outside air mode automatically when the engine switch is turned off OFF or ON Customized value displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -

f.

Enter the following menus: Body Electrical / Engine and ECT / Data List.


g.

Check the value(s) by referring to the table below.

Powertrain > Engine and ECT
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/C Signal Magnet clutch on request signal ON or OFF ON: "A/C" switch on
OFF: "A/C" switch off
Operate with the engine idling and the blower switch on (LO level).


ACTIVE TEST


Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Magnetic Clutch Relay Magnet clutch relay OFF/ON Operates with the engine started and the vehicle stopped
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (front side air mix) target pulse Min.: 128
Max.: 383
·

Operates between 165 and 257 pulses (for LHD)

·

Operates between 255 and 347 pulses (for RHD)


Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (front mode) pulse Min.: 128
Max.: 383
·

Operates between 143 and 257 pulses (for LHD)

·

Operates between 255 to 369 pulses (for RHD)


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (recirculation) target pulse Min.: 128
Max.: 383
Operates between 235 and 258 pulses
A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly (rear mode) pulse Min.: 128
Max.: 383
·

Operates between 253 and 276 pulses

·

w/ Rear Face Register