Home › Engine / Hybrid System › 2GD-FTV EMISSION CONTROL › EGR BYPASS VALVE SWITCHING VALVE
RM33J0E _51 Engine / Hybrid System _038440 2GD-FTV EMISSION CONTROL _0201058 EGR BYPASS VALVE SWITCHING VALVE G

2GD-FTV EMISSION CONTROL  EGR BYPASS VALVE SWITCHING VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY

a.
A346703C01
1.25,0.844 1.833,0.844 true 0.75,0.583 0.917,0.583 0.917,0.583 1.167,0.833 true 0.083,0.083 0.333,0.25 0.25,0.167 10 false *a 0.635,0.479 0.802,0.646 0.167,0.167 10 false 1 1.875,0.74 2.042,0.906 0.167,0.167 10 false 2
*a Component without harness connected
(No. 1 vacuum switching valve assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 1 MΩ or higher


If the result is not as specified, replace the No. 1 vacuum switching valve assembly.


b.

Check operation of the No. 1 vacuum switching valve assembly.

i.
A346704C01
2.646,0.354 2.479,0.354 2.479,0.354 2.094,0.813 true 2.875,2.875 2.792,2.875 2.792,2.875 2.625,2.625 false 1.365,2.885 1,3 1,3 0.875,3 true 1.542,2.688 1.292,2.188 1.292,2.188 1.125,2.188 true 2.667,0.24 2.833,0.406 0.167,0.167 10 false *a 0.375,2.104 0.625,2.26 0.25,0.156 10 false *b 0.969,2.083 1.219,2.25 0.25,0.167 10 false *c 2.896,2.771 3.125,2.927 0.229,0.156 10 false *e 0.719,2.885 0.948,3.042 0.229,0.156 10 false *d
*a Vacuum
*b Air
*c Port E
*d Port F
*e Filter


When a vacuum of 60 kPa (450 mmHg, 18 in.Hg) is applied to port F, check that air flows from port E to the filter.


ii.
A346705C01
1.135,1.51 0.74,1.354 0.74,1.354 0.573,1.354 true 1.313,1.5 0.99,1.969 0.99,1.969 0.823,1.969 true 1.896,0.854 2.417,0.854 true 1.438,0.51 1.594,0.51 1.594,0.51 1.781,0.844 true 0.417,0.667 0.667,0.833 0.25,0.167 10 false *a 0.417,1.26 0.594,1.417 0.177,0.156 10 false *b 0.667,1.865 0.896,2.031 0.229,0.167 10 false *c 2.448,0.75 2.594,0.927 0.146,0.177 10 false 2 1.333,0.406 1.479,0.583 0.146,0.177 10 false 1
*a Air
*b Port F
*c Port E


Apply battery voltage 12V across terminals 1 and 2.


iii.

Check that air flows from port E to port F.