SPECIFICATIONS POWER ASSIST SYSTEMS SERVICE DATA
Power Steering Fluid
| Power Steering Fluid
|
Automatic transmission Fluid DEXRON II or III or equivalent
|
| Maximum fluid level increase
|
5 mm (0.197 in.)
|
| Fluid pressure at idle speed with valve closed (Maximum fluid pressure)
|
for GD Engine
|
9300 to 10000 kPa (94.9 to 101 kgf/cm2, 1349 to 1450 psi)
|
| for KD Engine
|
8800 to 9300 kPa (89.8 to 94.8 kgf/cm2 1276 to 1348 psi)
|
| for TR Engine
|
8800 to 9300 kPa (89.8 to 94.8 kgf/cm2 1276 to 1348 psi)
|
| Fluid pressure at engine speeds of 1000 rpm and 3000 rpm (Standard fluid pressure difference)
|
490 kPa (4.99 kgf/cm2, 71 psi) or less
|
| Fluid pressure at idle speed with valve fully open and turn the steering wheel to the full lock position (Maximum fluid pressure)
|
for GD Engine
|
9300 to 10000 kPa (94.9 to 101 kgf/cm2, 1349 to 1450 psi)
|
| for KD Engine
|
8800 to 9300 kPa (89.8 to 94.8 kgf/cm2 1276 to 1348 psi)
|
| for TR Engine
|
8800 to 9300 kPa (89.8 to 94.8 kgf/cm2, 1276 to 1348 psi)
|
Vane Pump
| Vane pump shaft and vane pump housing oil maximum clearance
|
0.07 mm (0.00276 in.)
|
| Vane pump rotor groove and vane pump plate maximum clearance
|
0.025 mm (0.000984 in.)
|
| Compression spring free minimum length (Reference)
|
30.26 mm (1.19 in.)
|
| Vane pump rotating torque
|
0.27 N*m (3 kgf*cm, 2 in.*lbf) or less
|