Home › General › SPECIFICATIONS › 1KD-FTV INTAKE / EXHAUST
RM33J0E _V1 General _038516 SPECIFICATIONS _0178150 1KD-FTV INTAKE / EXHAUST F

SPECIFICATIONS  1KD-FTV INTAKE / EXHAUST  SERVICE DATA  


INTAKE SYSTEM
Turbocharger pressure Condition Specified Condition
Engine speed
(approximately 4600 rpm)
15 to 45 kPa (0.15 to 0.46 kgf/cm2, 2.1 to 6.5 psi)

INTAKE MANIFOLD
Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground 20°C (68°F) 10 kΩ or higher
2 - Body ground

EXHAUST MANIFOLD w/ TURBOCHARGER
Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00440 in.)

EXHAUST PIPE
Compression spring Minimum length 40 mm (1.57 in.)