23670
1.INSPECT INJECTOR ASSEMBLY
| *a | Component without harness connected
(Injector Assembly) |
| *b | No. 1 Injector Assembly - #1
No. 2 Injector Assembly - #2 No. 3 Injector Assembly - #3 No. 4 Injector Assembly - #4 |
| *c | No. 1 Injector Assembly - #10
No. 2 Injector Assembly - #20 No. 3 Injector Assembly - #30 No. 4 Injector Assembly - #40 |
for i-ART:
Inspect the injector assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (GND) - 4 (Vout) | 25°C (77°F) | 16.4 kΩ or less |
| 2 (VC) - 4 (Vout) | 3.5 kΩ or less |
If the result is not as specified, replace the injector assembly.
Measure the resistance according to the value(s) in the table below.
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| No. 1 Injector Assembly | 3 (#1) - 6 (#10) | 20°C (68°F) | 0.52 to 0.66 Ω |
| No. 2 Injector Assembly | 3 (#2) - 6 (#20) | ||
| No. 3 Injector Assembly | 3 (#3) - 6 (#30) | ||
| No. 4 Injector Assembly | 3 (#4) - 6 (#40) |
The temperature indicated in "Condition" is the temperature of the injector assembly.
If the result is not as specified, replace the injector assembly.
except i-ART:
Inspect the injector assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 0.52 to 0.66 Ω |
The temperature indicated in "Condition" is the temperature of the injector assembly.
If the result is not as specified, replace the injector assembly.