89465
1.INSTALL HEATED OXYGEN SENSOR
| *a | Fulcrum Length |
Using SST, install the heated oxygen sensor.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 39.4 N*m (402 kgf*cm, 29 ft.*lbf)
for Pre-Runner:
Attach the sensor wire to the 4 clamps.
for 4WD:
Attach the sensor wire to the clamp.
Connect the heated oxygen sensor connector.
2.INSPECT FOR EXHAUST GAS LEAK