27330
1.INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor assembly for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Slip ring | 20°C (68°F) | 1.2 to 2.4 Ω |
If the result is not as specified, replace the generator rotor assembly.
Check if the generator rotor is grounded.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Rotor core | Always | 10 kΩ or higher |
If the result is not as specified, replace the generator rotor assembly.
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
Using a vernier caliper, measure the diameter of each slip ring.
13.3 to 13.4 mm (0.524 to 0.528 in.)
12.9 mm (0.508 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
2.INSPECT BRUSH
| *a | Length |
Using a vernier caliper, measure the exposed brush length.
13.7 mm (0.539 in.)
7.0 mm (0.276 in.)
If the exposed length is less than the minimum, replace the generator regulator assembly.
27403
3.INSPECT GENERATOR PULLEY SET
| *a | Free |
| *b | Lock |
Hold the center of the generator pulley set, and confirm that the outer ring turns counterclockwise and does not turn clockwise.
The outer ring turns counterclockwise and does not turn clockwise.
If the result is not as specified, replace the generator pulley set.