2TR-FBE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27330 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A386242

Check the generator rotor assembly for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.2 to 2.4 Ω

If the result is not as specified, replace the generator rotor assembly.



b.
A386243

Check if the generator rotor is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 kΩ or higher


If the result is not as specified, replace the generator rotor assembly.



c.

Check that the slip rings are not rough or scored.

If rough or scored, replace the generator rotor assembly.


d.
A117279

Using a vernier caliper, measure the diameter of each slip ring.

Standard diameter:

13.3 to 13.4 mm (0.524 to 0.528 in.)


Minimum diameter:

12.9 mm (0.508 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.


Hide 2.INSPECT BRUSH

A386271C01
2.156,0.927 2.5,1.104 0.344,0.177 10 true *a
*a Length


a.

Using a vernier caliper, measure the exposed brush length.

Standard exposed length of new brush:

13.7 mm (0.539 in.)


Minimum exposed length:

7.0 mm (0.276 in.)


If the exposed length is less than the minimum, replace the generator regulator assembly.


Hide 27403 3.INSPECT GENERATOR PULLEY SET

a.
A386244C01
0.667,0.24 0.865,0.417 0.198,0.177 10 false *a 2.469,0.167 2.719,0.344 0.25,0.177 10 false *b
*a Free
*b Lock


Hold the center of the generator pulley set, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

OK:

The outer ring turns counterclockwise and does not turn clockwise.


If the result is not as specified, replace the generator pulley set.