Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR(for Automatic Air Conditioning System)
RM3270E _58 Vehicle Interior _041713 HEATING / AIR CONDITIONING _0199999 SOLAR SENSOR(for Automatic Air Conditioning System) G

HEATING / AIR CONDITIONING  SOLAR SENSOR(for Automatic Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 88625H 1.INSPECT COOLER THERMISTOR (SOLAR SENSOR)

a.
E324407C02
0.771,0.698 1.135,0.917 0.365,0.219 1.51,1.656 1.875,1.875 0.365,0.219 1.083,3.125 1.344,3.125 1.344,3.125 1.635,2.75 true 2.385,3.115 2.146,3.115 2.146,3.115 2.042,2.75 true 1.094,1.156 1.469,1.156 true 1.865,1.156 2.24,1.156 true 1.563,1.677 2.021,1.875 0.458,0.198 10 false G37 0.865,0.729 1.146,0.927 0.281,0.198 10 false H4 0.74,3.052 1.354,3.25 0.615,0.198 10 false S5-3 2.427,3.042 3.042,3.24 0.615,0.198 10 false TSD 0.781,1.083 1.24,1.281 0.458,0.198 10 false SS+ 2.292,1.073 2.75,1.271 0.458,0.198 10 false SS- 0.583,0.167 0.896,0.323 0.313,0.156 10 false *a 0.677,1.635 0.99,1.792 0.313,0.156 10 false *b
*a Component without harness connected
(Cooler Thermistor (Solar Sensor))
*b Component without harness connected
(Air Conditioning Amplifier Assembly)


Check the wire harness.

i.

Disconnect the G37 air conditioning amplifier assembly connector.


ii.

Disconnect the H4 cooler thermistor (solar sensor) connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H4-1 (SS+) - G37-30 (S5-3) Always Below 1 Ω
H4-2 (SS-) - G37-33 (TSD) Always Below 1 Ω
H4-1 (SS+) - Body ground Always 10 kΩ or higher
H4-2 (SS-) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.



iv.

Reconnect the G37 air conditioning amplifier assembly connector.


v.

Turn the ignition switch to ON.


vi.
E324408C01
1.604,0.417 1.948,0.625 0.344,0.208 1.219,1.802 1.604,1.802 true 1.979,1.792 2.365,1.792 true 1.698,0.427 2.01,0.625 0.313,0.198 10 false H4 0.906,1.719 1.365,1.917 0.458,0.198 10 false SS+ 2.406,1.719 2.865,1.917 0.458,0.198 10 false SS- 0.063,0.052 0.375,0.208 0.313,0.156 10 false *a
*a Component with harness connected
(Cooler Thermistor (Solar Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
H4-1 (SS+) - H4-2 (SS-) Engine switch off Below 1 V
H4-1 (SS+) - H4-2 (SS-) Engine switch ON 4.75 to 5.25 V


If the voltage is not as specified, replace the air conditioning amplifier assembly.




b.

Check the cooler thermistor (solar sensor).

i.

Reconnect the connector to the cooler thermistor (solar sensor).


ii.

Turn the ignition switch to ON.


iii.
E239588C12
0.292,1.031 0.75,1.313 0.458,0.281 1.833,1.125 2.281,0.604 2.281,0.604 2.542,0.604 false 1.615,1.135 1.135,0.604 1.135,0.604 0.865,0.604 false 0.146,0.156 0.438,0.479 0.292,0.323 10 false *a 0.573,0.531 0.958,0.781 0.385,0.25 10 false SS- 2.594,0.531 3,0.844 0.406,0.313 10 false SS+ 0.448,1.083 0.813,1.26 0.365,0.177 10 false H4
*a Component with harness connected
(Cooler Thermistor (Solar Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
H4-1 (SS+) - H4-2 (SS-) Sensor is subjected to electric light 0.8 to 4.3 V
H4-1 (SS+) - H4-2 (SS-) Sensor is covered with a cloth Below 0.8 V


NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 2 of the cooler thermistor (solar sensor).

·

Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

·

As the inspection light is moved away from the sensor, the voltage decreases.

·

Check from the rear of the connector while it is connected to the cooler thermistor (solar sensor).



If the voltage is not as specified, replace the cooler thermistor (solar sensor).